Various Installation Types
Figure 7A
Saddle Installation
Hang unit with suspended rods
and "U" channel members.
Threaded 
rod and U channel
(Supplied by others)
Vibration Isolators
(Supplied by others)
Figure 7B
Curb Mounted
Mount unit on wooden or metal
curb assembly. Unit must be raised
an adequate height for installation 
and slope of drain lines.
Curb is wood or metal
(Supplied by others)
May be anchored to 
floor,leaving space 
for drain connections
Vibration Isolators
(Supplied by others)
PVC Support Straps
(Supplied by others)
Figure 7C
Suspended
Unit Suspended using 
Polyester reinforced PVC support straps.
NOTE: When installing your HRV/ERV
flexible duct connectors should
be installed between the HRV/ERV
and the galvanized duct work.