Nordyne R-410A Electric Heater User Manual


 
19
Refrigerant Charging Charts for Heating Mode of Operation
13 SEER Split System Heating Charts
018K OUTDOOR TEMPERATURE (DEG. F)
0 102030405060
Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch.
Press Press. Temp. Press. Press. Temp. Press. Press. Temp. Press. Press. Temp. Press. Press. Temp. Press. Press. Temp. Press. Press. Temp.
37 212 108 52 232 111 66 252 114 81 273 117 96 285 125 114 311 139 131 338 153
38 219 106 53 238 109 67 257 112 82 276 115 97 292 123 115 318 135 132 345 147
39 226 104 54 244 107 68 262 110 83 280 113 98 299 120 116 325 130 133 352 141
40 233 102 55 250 105 69 267 108 84 284 111 99 306 117 117 332 126 134 359 134
41 240 100 56 256 103 70 271 106 85 287 109 100 313 114 118 339 121 135 366 128
42 247 98 57 261 101 71 276 104 86 291 107 101 320 111 119 346 117 136 373 122
43 254 96 58 267 99 72 281 102 87 295 105 102 327 108 120 353 112 137 380 116
024K OUTDOOR TEMPERATURE (DEG. F)
0 102030405060
Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch.
Press Press. Temp. Press. Press. Temp. Press. Press. Temp. Press. Press. Temp. Press. Press. Temp. Press. Press. Temp. Press. Press. Temp.
37 211 111 52 237 115 66 263 119 81 289 123 97 306 132 114 337 147 131 367 162
38 218 109 53 243 113 67 268 117 82 293 121 98 313 129 115 344 142 132 374 156
39 225 107 54 249 111 68 273 115 83 297 119 99 320 126 116 351 138 133 381 149
40 232 105 55 255 109 69 277 113 84 300 117 100 327 124 117 358 133 134 388 143
41 239 103 56 261 107 70 282 111 85 304 115 101 334 121 118 365 129 135 395 137
42 246 101 57 266 105 71 287 109 86 308 113 102 341 118 119 372 124 136 402 131
43 253 99 58 272 103 72 292 107 87 311 111 103 348 115 120 379 120 137 409 125