Nordyne 707831C Air Cleaner User Manual


 
AireCare TM Electronic Air Filter
For M1 and E2 Series Furnaces
Congratulations on your installation of an
AireCare TMElectronic Air Filter - the newest
and one of the most efficient ways to reduce
indoor air pollution in the home. Used
correctly, it will help protect your indoor
environment from allergy causing pollutants
such as pollen, plant spores, lung damaging
particles like tobacco and cooking smokes,
fungi, bacteria, and some viruses.
iMPORTANT: Read all instructions carefully
before starting the installation. Specifica-
tions or designs are subject to change or
discontinuance without notice and without
incurring obligations.
These instructions are primarily intended to
assist qualified individuals experienced in the
proper installation of heating and/or air condi-
tioning appliances. Some local codes require
licensed installation/service personnel for this
type of equipment.
WARNING:
improper installation may damage
equipment, create a hazard, and will
void thewarranty. DO NOT CONNECT
TO 110 Volts AC - the unit is designed
to operate on 24 VAC.
/!X DANGER:
Shut off electrical supply to the
furnace at the household breaker box
to prevent electrical shock and avoid
injury.
M1 AireCare TM Electronic Air Filter
Installation Instructions
Before starting this installation, make sure that
all electrical power to the furnace has been
disconnected.
The M1 AireCare TM Electronic Air Filter kit con-
sists of two brackets, four screws, a filter grille,
two protective edging strips, and the electronic
air filter with power cable. To install the kit, the
two brackets must be mounted onto the door of
the M1 furnace as shown in Figure 1.
Install the Brackets
1. install the protective sheet metal edging
strips into the upper left louver of the M1
door (See Figure 1).
2. Locate the bottom bracket (See Figure 1)
and remove the protective tape from the
back.
3. Place the bracket into the bottom louver of
the M1 door with the flange pointing to-
wards the top of the door. Permanently
mount the bracket to the door using two of
the supplied screws.
4. Locate the top bracket (See Figure 1) and
remove the protective tape from the back.
5. Place the bracket into the top louver of the
M1 door with the flange pointing towards
the bottom of the door. Permanently mount
the bracket to the door using two of the
supplied screws.
Install the Filter
1. Connectthe electronicairfilterpowerwires
(24 VAC) to the red and gray low voltage
terminals (R and C). Run this wire through
the left side of the top louver of the M1 door.
Connect the power wire marked with white
stripe or dash to C, the other to R. Place the
door on the furnace and latch.
2. Place the electronic air filter into the brack-
ets on the door by inserting it up into the top
bracket then allowing it to drop into the
bottom bracket.
3. Connect the electronic air filter power wire
jack into the filter. Power the furnace. The
AireCare TM Electronic Air Filter is active if
the light on top of the electronic air filter is lit.
4. Place the filter grille over the top bracket.
There are two tabs that attach the grille to
the top bracket. The grille will now fit over
the bottom bracket and is held there by a
permanent magnetic.