Napoleon Fireplaces ZCVF42 Indoor Fireplace User Manual


 
6
W415-0527 / 09.29.05
ANY CHANGE TO THIS ENCLOSURE CAN BE DANGEROUS AND IS PROHIBITED.
It is best to frame your ventless rebox enclosure after it is positioned. Use 2x4’s and frame to local building codes.
(FIGURE 3-5)
FRAMING
21 1/4"
42 1/2”
32 3/4"
21 1/4"
47 1/8”
35 3/4"
52 1/3”
42 1/2”
74 1/8”
55 5/8”
47 1/8”
78 5/8”
42 1/2"
21 1/4”
42 1/2”
OUTSIDE
CHASE
OUTSIDE
CHASE
INSIDE
CHASE
INSIDE
CHASE
6"
21 1/4"
47 1/8"
21 1/4”
47 1/8”
OUTSIDE
CHASE
OUTSIDE
CHASE
INSIDE
CHASE
INSIDE
CHASE
6"
21 1/4"
FIGURE 3
FIGURE 4
FIGURE 5
Minimum clearance to combustible construction from ventless firebox enclosure:
sides, back, bottom and top of the unit 0 inches
recessed depth 21 1/4 inches
Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the ventless rebox
enclosure body, it is recommended that the walls of the ventless rebox enclosure enclosure be “ nished” (ie: drywall/sheet-
rock), as you would nish any other outside wall of a home. This will ensure that clearance to combustibles is maintained
within the cavity.
When roughing in the ventless rebox enclosure, raise the ventless rebox enclosure to accommodate for the thickness of
the nished oor materials, i.e. tile, carpeting, hard wood.
Objects placed in front of the ventless rebox enclosure should be kept a minimum of 4 feet away from the front face.
ZCVF36 ZCVF42