Napoleon Fireplaces GT8P Indoor Fireplace User Manual


 
18
W415-0619 / B / 03.03.08
A. This replace is equipped with an ignition device which
automatically lights the burner. Do not try to light by hand.
B. Before operating, smell all around the replace area for
gas and next to the oor because some gas is heavier than
air and will settle on the oor.
C. Do not use this replace if any part has been under water.
Immediately call a quali ed service technician to inspect the
replace and replace any part of the control system and any
gas control which has been under water.
When lit for the rst time, the replace will emit a slight odour for
a few hours. This is a normal temporary condition caused by the
curing of paints and lubricants used in the manufacturing process
and will not occur again. Simply open a window to suf ciently
ventilate the room.
After extended periods of non-operation such as following a
vacation or a warm weather season, the replace may emit a
Turn off all gas to the replace.
• Open windows.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re
department.
1. STOP! Read the safety information located above.
2. Turn off all electric power to the replace.
3. This replace is equipped with an ignition device which
automatically lights the burner. Do not try to light by hand.
4. Remove the glass door.
5. Wait ve (5) minutes to clear out any gas. If you smell gas
including near the oor STOP! Follow “B” in the above safety
information on this label. If you don’t smell gas go to the next
step.
6. Replace the glass door.
7. Turn on all electric power to the replace.
8. Turn the replace switch to the ON position.
9. If replace will not operate, follow instructions “To Turn Off
Gas” and call your service technician or gas supplier.
FOR YOUR SAFETY READ BEFORE LIGHTING:
LIGHTING INSTRUCTIONS
WHAT TO DO IF YOU SMELL GAS:
FIGURE 32
slight odour for a few hours. This is caused by dust particles in
the heat exchanger burning off. Open a window to suf ciently
ventilate the room.
Purge all gas lines with the glass door of the replace open.
Assure that a continuous gas ow is at the burner before
closing the door.
OPERATING INSTRUCTIONS
1. Turn the replace switch to the OFF position.
2. Turn off all electrical power to the replace if service is to
be preformed.
3. Turn manual shut-off valve clockwise to off.
Do not force.
TO TURN OFF GAS
CERTIFIED UNDER : CSA 2.22-2007, ANSI 21.50-2007 VENTED GAS FIREPLACE
DIRECT VENT GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED SITTING ROOM INSTALLATION.
SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA
Z240MH SERIES GAS EQUIPPED MOBILE HOMES. IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONSTRUCTION AND SAFETY STANDARD. TITLE 24 DFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE
THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES,
ANSI/NFPA 501A.
I
N
T
E
R
T
E
K
W
a
r
n
o
c
k
H
e
r
s
e
y
CM
CUS
ALTITUDE
INPUT
ORIFICE
MANIFOLDPRESSURE:3.5"WATERCOLUMN
MINIMUMSUPPLYPRESSURE:4.5"WATERCOLUMN
MAXIMUMSUPPLY PRESSURE:7.0" WATERCOLUMN
MANIFOLDPRESSURE:10" WATERCOLUMN
MINIMUMSUPPLYPRESSURE:11"WATERCOLUMN
MAXIMUMSUPPLYPRESSURE:13" WATERCOLUMN
0-4500FT(0-1370m)
6,000BTU/h
#69
0-4500FT(0-1370m)
6,000BTU/h
#56
CERTIFIED FOR CANADA AND USA
GT8N
MODEL
GT8P
MODEL
W385-0381 / A
GT8
VENTED GAS FIREPLACE NOTFORUSEWITHSOLIDFUEL.FORUSEWITHGLASS
DOOR. CERTIFIED WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO THE
APPLIANCE, WHICH WILL COME IN CONTACT WITH
THE FLAMES, OTHER THAN THAT SUPPLIED BY THE
MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP 6” RECESSED DEPTH 7”
FLOOR 0” VENT 1”
SIDES 0” BACK 1 1/2”
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS
ARE 10 INCHES AND 10 FEET RESPECTIVELY.
MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS
ARE 36 INCHES AND 10 FEET RESPECTIVELY.
MADEINCANADA
WOLFSTEELLTD,BARRIE,ON,CANADA
SERIALNUMBER:
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT
KITS, SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER
REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE
VENT-AIR INTAKE SYSTEM.
ELECTRICAL RATING: 115v 0.82AMP, 60HZ
REFERENCE #15901
TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL.
(NATURAL GAS)
(PROPANE)
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE
RATING PLATE AND MY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY
LOCATED, MANUFACTURED HOME (USA ONLY) OR MOBILE HOME WHERE NOT
PROHIBITED BY LOCAL CODES. SEE OWNER’S MANUAL FOR DETAILS. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A
CERTIFIED KIT IS USED.
RATING PLATE
RATING LABEL LOCATION: The rating label is located under the control panel and is chained to the replace.
DO NOT REMOVE.