The Napoleon gas fireplace insert comes standard with a
blower, a heat sensor, variable on/off speed control and a
power cord. Because the blower is thermally activated,
when turned on, it will automatically start approximately 15
minutes after lighting the fireplace and will run for approxi-
mately 30 minutes after the fireplace has been turned off.
Use of the fan increases the output of heat. Air, drawn in
through the lower louvre access door, is driven up the back
of the firebox, and exhausted as hot air between the upper
louvres.
• Turn off the gas and electric power to the unit.
• Remove the upper glass bracket. Loosen the lower glass
bracket and remove the glass.
• Remove the logs.
• Remove the burner assembly.
• Remove the eight screws holding the access door in
place on the control assembly (located at the back of the
burner support).
• Remove the four screws holding the blower duct and
slide it forward from beneath the burner support.
• Disconnect the electrical connectors at the blower.
• Remove the blower.
1. Remove the pilot adjustment cap.
2. Adjust the pilot screw to provide properly sized flame.
3. Replace the adjustment cap.
Natural gas models have air shutters set at 1/16 (.063")
inch open. Propane gas models have air shutters set at 3/
16 (.188) inch open. Closing the air shutter will cause a
more yellow flame, but can lead to carboning. Opening the
air shutter will cause a more blue flame, but can cause
flame lifting from the burner ports. The flame may not ap-
pear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A
QUALIFIED GAS INSTALLER!
PILOT SCREW
BLOWER SYSTEM
BLOWER REPLACEMENT INSTRUCTIONS
ADJUSTMENTS
PILOT BURNER ADJUSTMENT VENTURI ADJUSTMENT
Drywall dust will penetrate into blower bearings causing
irrepairable damage and must be prevented from coming
into contact with the blower or its compartment.
Any damage resulting from this condition is not covered
by the warranty policy.