Napoleon Fireplaces BGNV36N Indoor Fireplace User Manual


 
10
W415-0275 / C / 09.23.05
Attach the connectors from
the black and white wires
to the thermodisc and se-
cure the thermodisc
bracket to the securing
stud at the bottom left of the
unit using a lock washer
and wing nut. Ensure that
the thermodisc touches
the firebox wall.
Attach the connectors from the black and
red wires to the blower.
Attach and secure the variable speed
switch using the nut provided. Plug the
harness cord into the receptacle.
The wire harness provided in this kit is a universal
harness. When installed, ensure that any excess
wire is contained, preventing it from making con-
tact with moving or hot objects.
Because the blower is thermally activated, when
turned on, it will automatically start approximately
15 minutes after lighting the fireplace and will run
for approximately 30-45 minutes after the fireplace
has been turned off. Use of the fan increases the
output of heat.
Drywall dust will penetrate into the blower bear-
ings causing irreparable damage. Care must be
taken to prevent drywall dust from coming into
contact with the blower or its compartment. Any
damage resulting from this condition is not cov-
ered by the warranty policy.
A
B
INSTALLATION TO BE
DONE BY A QUALIFIED
INSTALLER and must be
electrically connected and
grounded in accordance
with local codes. In the ab-
sence of local codes, use
the current CSA C22.1
CANADIAN ELECTRICAL CODE in
Canada or the
ANSI/NFPA 70 NATIONAL
ELECTRICAL CODE in the United States.
The three slots allow ease
of adjustment of the
blower. For a quiet run-
ning blower, do not allow
the assembly to sit on the
firebox base.
Slide the vibration reducing pad (A) into the clip and onto
the threaded stud (B) at the other end, piercing a hole into
the pad. The blower must be able to be positioned entirely
onto the pad.
Tilt the blower onto its side. Slide it past the controls and
into the clip (C). Secure to the threaded stud using the lock
washer and wing nut provided. Ensure that the blower
does not touch the fireplace base or the firebox.
C
A
B
OPTIONAL BLOWER INSTALLATION
FIGURE 22 FIGURE23
red
white
black
FIGURE 20
ADJUSTMENT
SLOTS
FIGURE 21
THERMODISC
GROUND
SCREW
JUNCTION
RECEPTACLE /
BOX
FIGURE 24
FIGURE 25