Napoleon Grills WF 9 Indoor Furnishings User Manual


 
11
PIPING DIAGRAM WITH UV-LIGHT
TO
ELECTRICAL
OUTLET
1
3
2
4
9X
N570-0043 (8-32 X 3/4")
B
A
FROMWATERFALL
DRAINTO BASIN
FROMTHREEWAY
VALVE TO
WATERFALL
FROMBASIN TO
WATERFALLDRAIN
OVERFLOW
PROTECTION
PURGELINE
FROMWATER
SOURCETO
FLOAT VALVE
B
A
TODRAIN
FROMTHREEWAY
VALVE TO WATERFALL
SADDLE VALVE
FLOWCONTROL
VALVE/ PURGE
VALVE
INSTALLTHESUPPLIED
HOSECLAMPSONEITHER
SIDEOFTHEBASIN
SEDIMENT
FILTER
UV
LIGHT
Remove components from basin and assemble as shown. The fittings required are already attached to the filter and basin.
When using the optional UV light, the barbed elbow fitting on the “IN” side of the filter will need to be removed and threaded into the
elbow at the bottom of the UV light. Then connect the UV light directly to the sediment filter. Use teflon tape to seal these connec-
tions. Ensure that the supplied ground wire is connected from the grounding terminal on the UV light to either grounded copper
plumbing, or the ground in your electrical system. Use the supplied short piece of black tubing to run from the pump to the UV light.
Measure and cut the lines to the length necessary, push onto the barbed fittings and secure with the supplied hose clamps. Leak
test the waterfall before fully enclosing.