Napco Security Technologies GEM-P9600 Door User Manual


 
9
Key Fob Transmitters
Keyfobs can be programmed as “Arm/Disarm” devices using the ON and OFF
buttons (refer to control panel installation instructions).
Press the A button and for each Key Fob Transmitter, enter:
1 The Key Fob Transmitter number (01–15).
2 The area number to which transmitter is assigned (1 or 2); enter 0 to disable
keyfob.
3 The 6-digit RF ID # printed on the transmitter (enter all numbers and/or
letters, including leading “0”s, if any).
4 The 1-digit checksum number printed on transmitter.
5 The Aux-1 Option (see key fob Aux 1 & Aux 2 options).
6 The Aux-2 Option (see key fob Aux 1 & Aux 2 options).
Press Jto save. Then go to step 1
to enter next Key Fob.
When all Key Fobs are entered, press NEXT (E) button to proceed.
Note: If the Key Fob is converted for Two Button “Emergency Use”
(by cutting an internal jumper), both top or bottom buttons must be
depressed to activate an alarm. In this case, the Key Fob may not be
used to arm or disarm the contrl panel.
Key Fob Zone Assignment
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 = point
3; A2 = point 4. Up to 32 key fobs (using 1 button) or 16 key fobs (using 2 buttons) or 8 key fobs (using all 4 buttons) or any
combination up to a maximum of 32 controlled zones can be assigned, providing multiple wireless panic buttons on a
system, each reporting to the Central Station or a pager and/or annunciating on a keypad the key fob zone number with
description/location. To assign a key fob to a zone: program the keyfob as you would a transmitter, entering the keyfob's ID
code, check sum and point number at the appropriate zone. The “Quick Method” is not allowed. The zone may be
hardwired to a sensor as well as assigned to a key fob (either one will activate the zone alarm output). NOTE: If assigning
a key fob to a zone, the “ON/OFF” buttons on the key fob will no longer arm/disarm the system. The key fob is converted
to a “panic only” device.
Dealer Code
Press the A button directly enter the Dealer Code (default = 456789),
including leading zeros. Use the 1 through 9 buttons. NOTE: Press
the 0 button for a zero. Press Jto save.
Re-enter the Dealer Code.
Press Jto save. Press NEXT (E) button to proceed.
ZONE DESCRIPTIONS: GEM-R3DGTL cannot be used to enter Zone Descriptions. To enter Zone Descriptions you must
use the GEM-RP1CAe2 Keypad or the Napco Quickloader Software.
DATA
ENTRY
AUX 1/AUX 2
OPTIONS
•(blank) None
9 Keypad Panic
0 Aux K.P. Panic
B Instant
C Toggle Aux Relay
D Access Control
EXIT DEALER PROGRAM MODE: This completes the custom default program. Press the C button to enter the
Direct Address Program Mode for further programming or press the C button once again to end all programming and
resume normal keypad operation.
(Direct Entry)
16
INTERIOR
BYPASS FIRE/TBL SYS TBL CHIME
INTERIOR
BYPASS SYS TBL CHIME
FIRE/TBL
NOTE: When programming the ID Code number:
“A” = G 0 ; “B” = G 1 ;
“C” = G 2 ; “D” = G 3 ;
“E” = G 4 ; “F” = G 5 .
KeyFob # Area # 6-digit RF ID # Checksum # Aux1 # Aux2 #
(Direct Entry)
17
INTERIOR
BYPASS FIRE/TBL SYS TBL CHIME
INTERIOR
BYPASS SYS TBL CHIME
FIRE/TBL
rE
INTERIOR
BYPASS FIRE/TBL SYS TBL CHIME
Programming the GEM-P816 & GEM-P1632