Multiquip ST61460 Septic System User Manual


 

SPECIFICATIONS


   

Centrifugal Centrifugal Centrifugal Centrifugal

Chrome Steel Chrome Steel Chrome Steel Chrome Steel

4.00 (101) 4.00 (101) 6.00 (152) 6.00 (152)

0.60 in (15.2)


423 (1,600) 423 (1,600) 674 (2,450) 674 (2,450)

138 ft. (42.1) 138 ft. (42.1) 105 ft. (32.5) 105 ft. (32.5)

10 (7.5) 10 (7.5) 15 (11) 15 (11)

60

230 (3Ø) 460 (3Ø) 230 (3Ø) 460 (3Ø)

172.2 (230) 85.8 (460) 258 (230) 129 (460)

28.6 (230) 14.3 (460) 43 (230) 21.5 (460)


140°F (60°C)

40 (1,200) 47 (1,400)

ISO VG32 or Equivalent

See Note 2 See Note 2 See Note 2 See Note 2

3,600

IP68

F

33 (10)

205 (93) 205 (93) 301 (137) 301 (137)

See Note 3 See Note 3 See Note 3 See Note 3

 – Let pump hang freely from a lifting device. Start and stop pump while observing movement (kick) of
pump. If connected correctly the impeller will rotate clockwise (CW) as viewed from above. If pump rotates counterclockwise
interchange any two phases from the power source.

 – Use ISO VG32 lubrication oil, Mobile DTE 24 turbine oil 90 or equivalent. Fill oil chamber 75%
to 85% full (allow air space for expansion).

 - For unattended operation, CB1269, CB1274, CB1456, or CB1463 Control Boxes (Table 4) are required.
All control boxes provide thermal overload protection.