Multiquip SS233 Septic System User Manual


 
SS233 SUBMERSIBLE PUMP • OPERATION AND PARTS MANUAL — REV. #2 (03/22/10) — PAGE 11
OPERATION
1. Attach a suitable lifting cable (rope) to the carrying
handle (Figure 2) on the pump and lower the pump
into place. For applications where there is an excessive
amount of mud, grit or silt, the use of a support platform
is desirable. When pumping water from swimming pool
type applications where there is little or no debris, the
support platform is not required.
Figure 2. Submersible Pump Upright Position
(Correct)
LIFTING
ROPE
2.00-INCH
DISCHARGE
HOSE
POWER
CORD
SUPPORT
PLATFORM
3
3
2. Make sure the pump is always placed in an upright
position, not tilted (Figure 3). Never position the pump
directly on a soft, loose bottom. Remember to attain
maximum pumping capacity and prevent excessive
wear, position the pump so it will not burrow itself into
sand or clay.
Figure 3. Submersible Pump Upright Position
(Incorrect)
3. After the pump has been positioned correctly into place,
power can be applied to the pump's electric motor.
3
3