Multiquip QP-204H Water Pump User Manual


 
QP-204H CENTRIFUGAL PUMP — OPERATION AND PARTS MANUAL— REV. #3 (06/05/06) — PAGE 21
QP-204H — MAINTENANCE (PUMP)
-15
-30
-10
-5
in. Hg
kPa
WIKA
R
-100
-80
-60
-40
-20
ACCEPTABLE READING
SHOULD BE BETWEEN
-25 AND -20 IN. HG.
25 IN. HG. TRANSLATES
INTO 25 FEET OF LIFT
AT SEA LEVEL.
PLACE VACUUM TESTER
OVER PUMP SUCTION PORT
CAUTION
DO NOT RUN PUMP
WITHOUT WATER.
-25
-20
DISCHARGE
PORT
PUMP VACUUM
TESTER
DIRECTION
OF WATER
FLOW
WATER HOSE
SOURCE
WATER
Pressure reading may vary
depending on altitude. See Tables 3
and 4.
NOTE
Figure 18. Pump Vacuum Tester