Mr. Heater HS125FAV Electric Heater User Manual


 
Color Length From To
Yellow 18" (406mm) High Limit Ignition Control Temp. Terminal
Yellow 18" (406mm) High Limit Ignition Control Temp Terminal
55FAV, 85FAV, 125FAV
WIRING CHART (Wire: Type AWG 150
o
C or equivalent (Type SF2-200, **SGI-250
o
C))
WIRING DIAGRAMS
8
Operating Instructions and Owner’s ManualEnerco Group, Inc.| Forced Air Propane Construction Heater 70056 Rev. C 4/07
HIGH LIMIT
SWITCH
MOTOR
THERMOCOUPLE
TO WIRE
IGNITION CONTROL
TEMP
MOTOR
VAC INPUT
HV TRANS
GND
SCREW
G
W
BLINE CORD
O**
G
SPARK PLUG
Y
B
Y
B
VAC INPUT
MOTOR
TEMP
HV TRANS
IGNITION
CONTROL
TO WIRE
TO WIRE
115V
60HZ
TO JUNCTION
SPARK
PLUG
HIGH LIMIT
SWITCH
GND
SCREW
TEMP
MOTOR
VAC INPUT
MOTOR
B
W
COLOR CODE LEGEND
B BLACK
W WHITE
G GREEN
R RED
Y YEL
O ORG
FEMALE CONN.
RING CONN.
CONNECTION
DIAGRAM
SCHEMATIC DIAGRAM
NOTE: If any original wiring as supplied with the heater, must be replaced, It must be replaced with
Type AWG 105° C wire or its equivalent, except as indicated (Type SF 2.200, **SGI-250° C)