Morphy Richards VC71064 MUK Vacuum Cleaner User Manual


 
6
6
U
U
K
K
H
H
e
e
l
l
p
p
l
l
i
i
n
n
e
e
0
0
8
8
7
7
0
0
0
0
6
6
0
0
2
2
6
6
0
0
4
4
R
R
e
e
p
p
l
l
a
a
c
c
e
e
m
m
e
e
n
n
t
t
P
P
a
a
r
r
t
t
s
s
0
0
8
8
7
7
0
0
1
1
6
6
7
7
6
6
6
6
3
3
5
5
I
I
r
r
e
e
l
l
a
a
n
n
d
d
H
H
e
e
l
l
p
p
l
l
i
i
n
n
e
e
1
1
8
8
0
0
0
0
4
4
0
0
9
9
1
1
1
1
9
9
76
DUST CANISTER
Emptying
To obtain the best results from
your cleaner empty the dust
canister regularly, otherwise the
airflow and cleaning power will
be reduced.
1 Everytime the dust canister is
emptied, turn the yellow dial (a
minimum of 5 revolutions) prior
to pressing the dust canister
release button (this will agitate
the fine dust between the filter
pleats and restore the air flow)
2 Remove the dust canister from
the product by pressing the
dust canister release button
Lift up the lid and remove the
canister from the product,
pulling the dust canister away
from the product. C
3 Holding the dust canister over a
dustbin press the dust release
button as shown D, the bottom
of the dust container will drop
down to release the dirt.
4 Close the bottom of the dust
canister by pressing the base
upwards until it clicks into
place.
5 Refit the dust canister back into
the product. Make certain the
dust canister feet are located in
place.
6 Close the lid securely.
ALLERGY
SUFFERERS
If the allergy sufferer is
emptying the product it is
recommended that the
container is placed into a plastic
bag to empty
.
1 Place the container inside the
plastic bag, releasing the
container with one hand whilst
holding the top of the bag
closed with the other, leave the
dust to settle for a few seconds
bef
or
e car
efully r
emo
ving the
empty canister. The plastic bag
can then be sealed and
disposed of
.
FILTERS
Cleaning canister
filter
1 Access the filter assembly by
removing the lid. Press the lid
release button down then rotate
the lid. E.
2 Use the filter cleaning brush to
remove any fluff from the
outside of the mesh filter.
3 Rotate mesh filter anti-
clockwise to disassemble.
4 Shake the pleated filter to
remove any dust.
5 Both the mesh and pleated
filters may be washed (in cool
water only) but must be
thoroughly air dried before
refitting.
IMPORTANT: Do not use
detergents to clean the filter.
To re-assemble, locate the
pleated filter into the lid then
secure into place with the mesh
filter by rotating the mesh filter
clockwise.
Fit the lid with filter assembly
onto the canister then rotate
clockwise until it locks into
place.
Exhaust filter
The exhaust filter  is located
at the rear of the cleaner. Press
the catch and pull the exhaust
grille
away F. Pull the
bottom of the filter outwards so
the top of the filter unhooks
from the filter recess.
Foam filters may be washed (in
cool w
ater), thoroughly air-dried
and re-fitted. The pleated filters
used on the Aller
gy models
cannot be washed and should
be replaced every 6 months or
sooner depending on use.
OPEN
D
E
C
F
71064 Rev1 18/5/07 10:55 am Page 6