Monte Carlo Fan Company 5GMR52XXD Series Fan User Manual


 
Raise fan with downrod assembled to
the ceiling bracket and hang fan
assembly. Be sure to rotate the
downrod ball so that the notch in the
bracket engages the slot in the ball.
Install 4 x 25 watt candelabra base
bulbs included.
10
12
Place upper glass over downrod and
c
anopy onto the fan body.
9
A
lign hole in downrod with hole in
yoke and install cross pin. Install
d
ownrod into yoke. Install keeper
into cross pin.
7
Tighten 2 downrod set screws and
lock nuts.
8
Set dip switches on the Remote Tr
ansmitter and Remote
R
eceiver to the same settings. This must be done so the
units will communcate properly. If you have other fans you
can set to control from one transmitter by setting both
receivers the same as the transmitter. If you have more
than one fan with remote. You can set the dip switches to
different positiosns to have seperate control.
R
emote Transmitter Dip swtiches
Re
mote Receive
r Dip switches
11
Make wire connections to power source using
wire nuts pro
vided. Mak
e sure that no filiments
are outside of the wirenut. After making the
wire connections, the wires should be spread
apart with the grounded conductor and the
equipment
-grounding conductor on one side of
the outlet box and ungrounded conductor on
the other side of the outlet box.
16
Lift canopy to ceiling aligning the key hole slots
with the screws on the bottom of the mounting
bracket. Rotate the canopy counter clockwise
to lock in place. Tighten the screws to secure
the canop
y
. See inset for k
eyhole shape
17
Install remote receiver by sliding into opening in
the Mounting bracket. Make sure that the dip
switches on the T
ransmitter and the Receiver
are set to the same position. See Fig 31 for
remote oper
ation
14
A
ttach blade arms to blades using
the blade arm screws and washers
provided.
18
white
black
Make wiring connections as indicated above.
White from fan to white from remote mark
ed
N. Orange from fan to Orange from remote
mark
ed Light/up
. Blue from fan to blue from
remote marked down light. Black from fan to
Black from remote mark
ed L. White from
house to white from remote marked AC N .
Black from house to Black from remote
marked AC L. Connect all green ground wires
to Ground wire from House.
orange
blue
Green
white
black
House
Fan
15
fuses
F
an and light kit combinations o
v
er 35 lbs,
in both flush and downrod mode the safety
cable must be installed into the house struc-
ture beams using the 3” lag screws,washers,
and lock w
ashers. provided. Make sure that
when the safety cable is fully extended the
lead wires are longer than the cable and no
stress is placed on the lead wires.
13
Safety cable installation
Safety Cable
Lag Screw
safety
cable
3” lag
screw
lock
washer
washer