Monessen Hearth VWF24 Indoor Fireplace User Manual


 
To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the
product and all applicable building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this
brochure are for illustrative purposes only and are not intended for, nor should they be used as a substitute for the instructions packaged with the unit. Appearance and specifications of the
product are subject to change without notice. © 2008 Monessen Hearth Systems Co.
A Brand of Monessen Hearth Systems Co.
149 Cleveland Drive, Paris, Kentucky 40361
www.monessenhearth.com
Ver.02 MON9508
Monessen
Your Monessen Dealer:
HPBA
Hearth, Patio & Barbecue Association
MADE IN U.S.A.
Classic Colossal Manual Control Manual SPK Control Millivolt Control / HI-LOW Radiant
Series Series Fuel Minimum Hearth Area Minimum Hearth Area Minimum Hearth Area Heat
Model Log Size Log Size* Type Front Depth Back Height Front Depth Back Height Front Depth Back Height BTU/H Output
CSA VENTED GAS LOGS REFRACTORY
VWF18 18”24”NG----2413 1/2” 21” 16” 28” 13 1/2” 25” 16” 60,000 14,000
VWF18 18” 24” LP ----2413 1/2” 21” 16” 28” 13 1/2” 25” 16” 60,000 14,000
VWF24 24” 30” NG ----3013 1/2” 27” 16” 34” 13 1/2” 31” 16” 70,000 16,000
VWF24 24”30”LP----3013 1/2” 27” 16” 34” 13 1/2” 31” 16” 60,000 14,000
VWF30 30”36”NG----3613 1/2” 33” 16” 40” 13 1/2” 37” 16” 80,000 18,000
VWF30 30”36”LP----3613 1/2” 33” 16” 40” 13 1/2” 37” 16” 60,000 14,000
VWF36 36”- NG----4213 1/2” 39” 16” 46” 13 1/2” 41” 16” 90,000 22,000
VWF36 36”- LP----4213 1/2” 39” 16” 46” 13 1/2” 41” 16” 60,000 14,000
VWF18ST 18” - NG --------2816281660,000 14,000
VWF18ST 18” - LP --------2816281660,000 14,000
VWF24ST 24” - NG --------3416341670,000 16,000
VWF24ST 24” - LP --------3416341660,000 14,000
RADCO VENTED GAS LOGS
VWF18 18” 24” NG 22” 13” 19” 16” 24” 13 1/2” 21” 16” 28” 13 1/2” 25” 16” 80,000 18,000
VWF18 18” 24” LP 22” 13” 19” 16” 24” 13 1/2” 21” 16” 28” 13 1/2” 25” 16” 60,000 14,000
VWF24 24” 30” NG 28” 13” 25” 16” 30” 13 1/2” 27” 16” 34” 13 1/2” 31” 16” 90,000 20,000
VWF24 24” 30” LP 28” 13” 25” 16” 30” 13 1/2” 27” 16” 34” 13 1/2” 31” 16” 60,000 14,000
VWF30 30” 36” NG 34” 13” 31” 16” 36” 13 1/2” 33” 16” 40” 13 1/2” 37” 16” 90,000 22,000
VWF30 30” 36” LP 34” 13” 31” 16” 36” 13 1/2” 33” 16” 40” 13 1/2” 37” 16” 60,000 14,000
VWF36 36” - NG 38” 13” 37” 16” 42” 13 1/2” 39” 16” 46” 13 1/2” 41” 16” 90,000 22,000
VWF36 36” - LP 38” 13” 37” 16” 42” 13 1/2” 39” 16” 46” 13 1/2” 41” 16” 60,000 14,000
VWF18ST 18” - NG 24” 16” 20” 16” 24” 16” 24” 16” 28” 16” 28” 16” 80,000 18,000
VWF18ST 18” - LP 24” 16” 20” 16” 24” 16” 24” 16” 28” 16” 28” 16” 60,000 14,000
VWF24ST 24” - NG 28” 16” 26” 16” 30” 16” 30” 16” 34” 16” 34” 16” 90,000 20,000
VWF24ST 24” - LP 28” 16” 26” 16” 30” 16” 30” 16” 34” 16” 34” 16” 60,000 14,000
Manual Control Millivolt Control Radiant
Fuel Minimum Hearth Area Minimum Hearth Area Heat
Model Log Size Type Front Depth Back Height Front Depth Back Height BTU/H Output
VENTED GAS LOGS FIBER
NBV24N–N24F/LG24F 24" NG 26" 13 1/2" 17" 16" 26" 13 1/2" 18" 16" 50,000 15,000
NBV24P–N24F/LG24F 24" LP 26" 13 1/2" 17" 16" 26" 13 1/2" 18" 16" 50,000 15,000
NBV30N–N30F/LG30F 30" NG 32" 13 1/2" 23" 16" 32" 13 1/2" 24" 16" 65,000 17,000
NBV30P–N30F/LG30F 30" LP 32" 13 1/2" 23" 16" 32" 13 1/2" 24" 16" 65,000 17,000
Millivolt Control
Fuel Minimum Hearth Area BTU/H
Model Log Size Type Front Depth Back Height NG LP
VENTED GAS LOGS FIBER
TPB18 18" NG/LP 26" 13" 18" 17" 28,000 28,000
TPB24 24" NG/LP 29" 13" 22 1/4" 17" 38,000 34,000
TPB30 30" NG/LP 33" 13" 25 1/4" 17" 38,000 34,000
*When using Colossal Series Split River Oak and Weathered Pine
logs, use the burner specifications for the millivolt control for all
installations when sizing for minimum hearth area.