81D0107 29
OPERATING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, refer to instructions for Match Lighting Instructions, page 30.
4. Turn gas control knob clockwise to the OFF position and turn ON/OFF switch to OFF position.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!
Follow the instructions under What To Do If You Smell Gas, page 28.
6. From OFF position, turn the gas control knob counterclockwise
to IGN position. Push in
control knob for 5 seconds. NOTE: If you are running the heater for the fi rst time, it may be
necessary to press in the control knob for 30 seconds or longer to allow air to bleed out
of the gas piping.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting
off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
to the ON position.
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON
position.
11. If the gas logs will not operate, follow the instructions To Turn Off Gas To Heater below and call your
service technician or gas supplier.
Figure 34 - Pilot
Millivolt CONTROL LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO HEATER
1. Turn control knob clockwise to OFF position to completely shut off the heater.
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
Figure 35 - Controls
Piezo
Ignitor
Pilot
Switch
Hi/Lo Knob
On/Off/Pilot
Knob