Monessen Hearth ILDV20PV Indoor Fireplace User Manual


 
83D0511
ILDV20/ILDV30 Fireplace Insert
9


No combustibles (ie: drapes, doors) may be within, or swing within 36" of the front of the insert.






The insert must be installed on a noncombustible hearth extending a minimum of 1" from the
fireplace opening (local codes may require a larger hearth). The hearth must also extend to both
sides of the face (Refer to the table on Page 7).
12” (305 mm)
Maximum Depth
12”
(305 mm)
Side Wall
Combustible Mantel
Top Facing
Side Facing
3/4” (19 mm)
Maximum Depth
Combustible Facing
42” (1067 mm)
Minimum
10” (254 mm)
Minimum
12” (305 mm)
Minimum
FP1947
insert clearances
9/08
9”
(228 mm)
FP1947
Figure 3
Mantel Clearances
 Side clearance to com-
bustibles is 10" (54 mm) from
opening whether it is side wall
or mantel legs.