Monessen Hearth EYF24 Gas Heater User Manual


 
65D1009
14
EYF Series Unvented Gas Log Set




1. Connect the wires to the two .5" male connectors
located on the left side of the valve when facing the
unit. Page 19, Figure 16. Do not let wire touch grate or
burner.
. Stick velcro pads with self-adhesive backing to the right
side of remote receiver and to the left side of the unit.
Figure 17
3. Attach remote receiver with velcro pads. Control switch
must face forward.
 Heat reduces battery life. You can protect the
receiver and extend battery life by mounting the receiver
in a wall or other location outside the fireplace.


The millivolt system and individual components may be
checked with a millivolt meter having a 1-1000 mV range.
Conduct each check shown in chart by connecting meter
test leads to terminals as indicated.
A. Complete Millivolt System Check
(“A” Reading - Thermostat contacts CLOSED - Control
knob “ON” - Main burner should turn ON)
1. If reading is more than 175 millivolts and the au-
tomatic valve still does not come on, replace the
control.
. If the closed circuit reading (“A” reading) is less
than 175 millivolts, determine cause for low read-
ing, proceed to Section B.
B. Thermopile Output Reading Check
(“B” Reading - thermostat contacts OPEN - Main burn-
er OFF
1. Check gas pressure to the unit. If gas pressure is
within minimum and maximum on data plate, then
check pilot voltage, 500 millivolts minimum. If the
minimum millivolt reading is not obtainable, replace
pilot.
  
   
    
A Complete  & 3 Closed Minimum 175
System
B Thermopile 1 &  Open Minimum 500
Output
LO
HI
OFF
SKYTEC
H
OFF
ON
REMOTE
FP2540
install remote receiver
Remote
Receiver
Velcro
Pads
FP540
Figure 17 -
Install Remote Receiver