Monessen Hearth EYF18 Indoor Fireplace User Manual


 
18 65D1009
Test Port “OUT”
WARNING
CHECKING GAS PRESSURE
The heater gas inlet connection is a
3
/8" NPT at the valve. All units
have the inlet connection on the right side, when you face the unit.
To connect from the opposite side, route the pipe under the rear
portion of the unit.
When tightening up the joint to the valve, hold the valve securely
to prevent movement.
NPT Test Plug
MANUAL CONTROL (Figure 14)
The pressure regulator is preset and locked to dis-
courage tampering. If the pressure is not as specified,
replace the regulator with the correct part from the parts
list in this manual.
Remove
1
/8" NPT plug, located on side of regulator
body. Install fitting and tubing to pressure gauge. After
taking pressure reading, reinstall test plug. Check for
gas leaks.
MILLIVOLT CONTROL (Figure 15)
The valve regulator controls the burner pressure which
should be checked at the pressure test point.
Turn captured screw counter clockwise two or thre
turns and then place tubing to pressure gauge over test
point (Use test point “OUT” closest to control knob).
After taking pressure reading, be sure and turn captured
screw clockwise firmly to re-seal. Do not over torque.
Check for gas leaks.
Figure 14 - Pressure Test Point Location
Manual Control
Figure 15 - Pressure Test Point Location
Millivolt Control
Test all gas joints from the gas meter to the heater valve for leaks using a gas analyzer or soap and water solution after com-
pleting connection. DO NOT USE AN OPEN FLAME.
Check the gas pressure with the appliance burning and the control set to HIGH.
WARNING
Connecting directly to an
unregulated propane/LPG tank
can cause an explosion.