Monessen Hearth DFX24C Indoor Fireplace User Manual


 

5
DFX & DBX Series Vent Free Fireplaces

This vent-free fireplace must be mounted on the floor or
on the optional fireplace hearth.

This unvented gas heater requires no outside venting and
burns cleanly with high heating efficiency.
This zero-clearance unvented gas heater can be installed
against (or recessed into) any wall that is accessible to a
gas line.
FP2507
VFS DBX controls
Piezo
Ignition
Fireplace
Screen
Control
Knob
Figure 1 -
Unvented Gas Heater
(Control Access Door Shown Open)
On/Off Switch
FP507


   
Regulator Pressure Nat. 4.0” w.c. 3.5” w.c.
Pilot Regulator Nat. n/a 3.5” w.c.
Max. Inlet Pressure Nat. 10.5” w.c. 10.5” w.c.
Min. Inlet Pressure Nat. 5.0” w.c. 5” w.c.
Regulator Pressure LP 10.0” w.c. 10.0” w.c.
Max. Inlet Pressure LP 13.0” w.c. 13.0” w.c.
Min. Inlet Pressure LP 11.0” w.c. 11.0” w.c.

     
4DFXNMC Nat. Manual ,000 15,000
4DFXPMC LP Manual ,000 17,000
4DFXNVC Nat. Millivolt ,000 17,000
4DFXPVC LP Millivolt ,000 17,000
3DFXNVC Nat. Millivolt 6,000 0,000
3DFXPVC LP Millivolt 6,000 0,000
DBX4NTC Nat. T-Stat 10,000 --
DBX4PTC LP T-Stat 10,000 --

 For LP models an external regulator is required
to reduce supply pressure to a maximum of 13" w.c.

Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.

 - All gas to the gas logs is shut off at the
valve.
 - Valve position to light/maintain a standing
pilot.
 - Valve position to turn ON/OFF log set with
remote switch/thermostat.
 - Variable position to control flame height
(heat output). Both front and rear burners
are in operation to provide realistic glow
and yellow flame.

 - All gas to the gas logs is shut off at the
valve.
 - Valve position to light/maintain a standing
pilot.
 - Variable position corresponding to desired
temperature.

The gas log heater is fitted with a specially designed safety
pilot light which senses the amount of oxygen available in
the room and shuts the gas log heater off if the oxygen level
begins to drop below a satisfactory level. The pilot can only
be relit when adequate fresh air is available.

The millivolt gas log pilot is fitted with a millivolt generator
to provide power for remote activation.