Monessen Hearth DFS32NVC Indoor Fireplace User Manual


 
71D0532 15
H
D
G
F
A
C
E
1
/2"or
5
/8"
C
A
G
C
G
A
FIREPLACE FRAMING
If unit is to be “built in,” fireplace framing can be built before or after the appliance is set in place. BE SURE THAT ALL
PACKING MATERIAL HAS BEEN REMOVED FROM THE UNDERSIDE OF THE UNIT PRIOR TO SETTING
THE FIREBOX IN PLACE. Construct fireplace framing following Figures 9 through 12. Refer to Figure 2 on page 9 for
fireplace dimensions. The framing headers may rest directly on top of the firebox.
The fireplace may be installed directly on a combustible floor or a raised platform of an appropriate height. Do not place
fireplace on carpeting, vinyl, tile or other soft floor coverings. It may, however, be placed on flat wood, plywood, particle
board or other hard surfaces. Be sure fireplace rests on a solid continuous floor or platform with appropriate framing for
support and so that no cold air can enter from under the firebox.
Anchor fireplace to the side framing members using optional nailing flange kit. See installation instructions included
with the kit.
B
A
Figure 9 - Corner Installation
Figure 10- Inside Chase Installation
Figure 12- Recessed Installation
Figure 11 - Stud Location
Un nished/rough
framing surface
Un nished/rough
framing surface
Un nished/rough
framing surface
or
equivalent
clearance
for drywall/
nishing
5
/8" or equivalent
clearance for
drywall/ nishing
materials
DFS32NVC DFS36NVC DFS42NVC
DFS32PVC DFS36NVC DFS42NVC
A 37¼" 41¼" 47¼"
B 35" 35" 35"
C 29" 32" 38"
D 14
"
16" 19"
E 61¾" 68" 74"
F 30" 34½" 37½"
G 15½" 17½" 17½"
H 43¾" 48¾" 53"
WARNING
Optional bottom radiant panel
cannot be covered. Optional top
radiant panel can be covered as
shown in Figure 8.