Monessen Hearth CSVF30SPV Electric Heater User Manual


 
58D56002 11
D
Minimum
to Either
Side Wall
E
Minimum
A
G
G
D
Minimum
to Either
Side Wall
F Minimum
F
Minimum
36"
in Front
C
B
Mantel Clearance from
Top of Unit
Side, Measured from Top
Rear
Measured
from Back
Corner
Measured
From Top
Corners
Product
Min. Ceiling
from Floor
Max.
Protrusion Min. Height Right Left
A B C D E F G
VF20 72" 12" 16" 1" 1" ½" 1½"
VF30 72" 12" 18" 2" 2" 1" ½"
CLEARANCES / HEIGHT REQUIREMENTS
Side
Wall
Mantel
Figure 4 - Minimum Clearance to Walls and Ceiling
The dimensions shown in Figure 4 are minimum clearances to maintain in installing this
heater. Left and right clearances are determined when facing the front of the heater.
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood flooring, the appliance shall be installed on a metal, wood or noncombustible
material panel extending full width and depth of the appliance.
WARNING
Front View
Corner Installation
Wall Installation
Side View
Ceiling
Ceiling
Floor
Side
Wall
Floor