Monessen Hearth CSDV40SNV Stove User Manual


 
30
58D6056
CSDV Series Direct Vent Gas Stove






Purge air from the supply line as follows:
Open main shutoff valve.
Unscrew main pressure test point.
Leave inlet test screw open until gas
comes in.
When gas is flowing, tighten inlet screw
immediately.


      


You may check for gas leaks with the following
methods only:
Soap and water solution
An approved leak testing spray
Electronic sniffer
Check for gas leaks in each of the following locations:
Pipe from the gas supply line connection to the gas valve
Burner connections Field made joints / gas shutoff valve
Pilot Factory made joints
Each joint or connection All joints on valve and control body
1. Depress and turn knob counterclockwise
to pilot position.
2. Depress fully and hold pilot gas knob. The
electronic ignitor will automatically ignite the
pilot. Keep knob fully depressed for a few sec-
onds. Release and check that pilot continues
to burn.
If the pilot does not stay lit, repeat Steps 1 and 2.
Figure 42 -
Pilot Position

PILOT
O
F
F
P
I
L
O
T
O
N
FP1935
control knob pilot







