CSDV Series Direct Vent Gas Stove


This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
This appliance is not for use with solid fuels.
The appliance is approved for bedroom or bedsitting
room installations.
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
This appliance is mobile home approved.
The appliance must be properly connected to a venting
system.
The appliance is not approved for closet or recessed
installations.
For alcove installation see “Clearances,” Page 9.
ON
OFF
FP2724
CSDV controls
Pilot
Optional
Remote
Receiver
Door
Figure 1 -
CSDV Cast Iron Stove Controls
Hi/Lo Knob
On/Off
Switch
Optional Blower
Ignitor Box
Located Under
Right Front Leg
FP2724

Input ratings are shown in BTU per hour and are certi-
fied without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having
jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at eleva-
tions above 4,500 feet (1,370 m).

Natural Propane (LP)
Inlet Minimum 4.5” w.c. 11.0” w.c.
Inlet Maximum 10.5” w.c. 13.0” w.c.
Manifold Pressure 3.5” w.c. 10.0” w.c.
 
     
CSDV20NV Nat. 18.000 12,500 #43
CSDV20PV LP 19,000 15,000 #54
CSDV30NV Nat. 28,000 17,000 #35
CSDV30PV LP 28,000 21,000 #51
Front Rear
CSDV40NV Nat. 33,000 26,000 #46 #43
CSDV40PV LP 33,000 30,000 #57 1.45 mm
