Modine Manufacturing BD Gas Heater User Manual


 
Blower Sheave Motor Sheave
Drive Belt No. Max.
No. Browning Pitch Dia. Bore Pitch Dia. Bore
C188 A38 7 3/4 2.9 1/2
C189 A39 7 3/4 2.9 5/8
C190 A35 4 3/4 2.9 5/8
C191 A49 11 3/4 2.9 1/2
C192 A40 5 3/4 2.9 5/8
C193 A47 8 3/4 4.4 5/8
C194 A37 8 3/4 2.9 5/8
C195 A33 6 3/4 2.9 5/8
C196 A44 10 3/4 2.9 5/8
C197 A50 11 3/4 2.9 5/8
C198 A47 8 3/4 4.4 7/8
C199 A34 4 3/4 2.9 5/8
C200 A39 8 3/4 2.9 1/2
C201 A40 6 3/4 4.4 5/8
C202 A35 5 3/4 2.9 1/2
C203 A51 10 1 2.9 1/2
C204 A52 10 1 2.9 5/8
C205 A46 7 1 2.9 5/8
C207 A51 7 1 4.4 1-1/8
C208 A40 8 3/4 2.9 5/8
C209 A40 6 3/4 4.4 7/8
C210 A51 8 1 4.4 7/8
C211 A36 5 3/4 2.9 5/8
C212 A58 14 1 2.9 1/2
C213 A59 14 1 2.9 5/8
26
Blower Sheave Motor Sheave
Drive Belt No. Max.
No. Browning Pitch Dia. Bore Pitch Dia. Bore
C1 A29 4 3/4 2.9 1/2
C16 A48 8 1 2.9 5/8
C38 A41 6 3/4 2.9 5/8
C61 A30 4 3/4 2.9 5/8
C80 A45 7 3/4 4.4 7/8
C90 A35 6 3/4 2.9 1/2
C91 A33 4 3/4 2.9 5/8
C92 A36 6 3/4 2.9 5/8
C95 A42 7 3/4 2.9 1/2
C96 A43 7 3/4 2.9 5/8
C100 A50 8 1 4.4 5/8
C101 A50 9 1 2.9 5/8
C102 A49 9 1 2.9 1/2
C105 A54 10 1 4.4 5/8
C106 A52 9 1 4.4 5/8
C107 A45 6 1 2.9 5/8
C108 A52 9 1 4.4 7/8
C111 A52 8 1 4.4 1-1/8
C180 A54 10 1 4.4 7/8
C182 A36 8 3/4 2.9 1/2
C183 A33 6 3/4 2.9 1/2
C184 A43 10 3/4 2.9 1/2
C185 A37 7 3/4 2.9 1/2
C186 A38 7 3/4 2.9 5/8
C187 A35 5 3/4 2.9 5/8
Voltage 115/60/1 230/60/1 200/60/3 230/460/60/3 575/60/3
Mtr. Mtr. Total Total Mtr. Mtr. Total Total Mtr. Mtr. Total Total Mtr. Mtr. Total Total Mtr. Mtr. Total Total
HP Amps Rpm Amps Watts Amps Rpm Amps Watts Amps Rpm Amps Watts Amps Rpm Amps Watts Amps Rpm Amps Watts
1/4
5.4 1725 5.7 390 2.7 1725 2.9 390 1.2 1725 1.4 370 1.3/0.7 1725 1.6/0.8 370 0.6 1725 0.7 370
1
/3
5.0 1725 5.3 410 2.5 1725 2.7 410 1.9 1725 2.1 400 1.6/0.8 1725 1.8/0.9 400 0.6 1725 0.7 400
1
/2
8.5 1725 8.8 600 3.8 1725 4.0 600 2.3 1725 2.5 600 2.6/1.3 1725 2.8/1.4 600 0.9 1725 1.0 600
3
/4
11.0 1725 11.3 870 5.5 1725 5.7 870 2.9 1725 3.1 840 3.0/1.5 1725 3.2/1.6 840 1.1 1725 1.2 840
1
13.4 1725 13.7 1080 6.7 1725 6.9 1080 4.0 1725 4.2 1100 3.8/1.9 1725 4.0/2.0 1100 1.5 1725 1.6 1100
1
-1/2
15.4 1725 15.7 1490 7.7 1725 7.9 1490 5.2 1725 5.4 1500 5.2/2.6 1725 5.4/2.7 1500 1.9 1725 2.0 1500
2
- - - - - - - - 6.8 1725 7.1 1950 6.6/3.3 1725 6.8/3.4 1950 2.3 1725 2.4 1950
3
- - - - - - - - 10.6 1725 10.8 3300 8.8/4.4 1725 9.0/4.5 3300 4.0 1725 4.1 3300
5
- - - - - - - - 14.3 1725 14.5 4400 13.2/6.6 1725 13.4/6.7 4400 5.2 1725 5.3 4400
MOTOR DATA
➀ ➂ (see page 25)
Motor Data and Total Unit Power Requirements Blower BD Models
Blower Drive Numbers
Model Number Designations
PD 150 A E M 01 30
PD - Propeller
Unit
BD - Blower
Unit
Input
150 - 150,000 Btu/hr input
175 - 175,000 Btu/hr input
250 - 250,000 Btu/hr input
etc.
Control Code
30 - Complete Control Code
descriptions are shown on
page 27
Power Code
01 - Complete Power Code
descriptions
02 - are shown on page 25
etc.
Ignition Type
A – Standing Pilot
E – Intermittent Pilot
M - Unit is equipped with 2-stage
or mechanical modulation
Heat Exchanger
A - Aluminized
S - Stainless Steel
Rating Plate Identification
MODEL IDENTIFICATION PLATE
SERIAL NUMBER MODEL NUMBER
POWER CODE CONTROL CODE
01121010692
PD150AE
01
30
Serial Number Designations
01
12 101 10 97
MOTORSUPPLIER CODE
01 - Century
05 - Universal
etc.
S
ERIES IDENTITY NUMBER
Identifies which series of controls
were furnished on the unit.
F
AN OR BLOWER
SUPPLIER CODE
01 - Revcor
08 - Brookside
etc.
Y
EAR OF
MANUFACTURE
97 - 1997
98 - 1998
etc.
W
EEK OF
MANUFACTURE
10 - 10
th
week of 1997
25 - 25
th
week of 1997
etc.
Heater Parts from ACF Greenhouses