Notes w1 : Rating conditions (cooling) — Indoor : 80˚FDB, 67˚FWB, Outdoor : 95˚FDB, 75˚FWB
Operating Range
ITEM MODELS MS09NW MS12NN
Cooling capacity
Power consumption
EER [SEER]
INDOOR UNIT MODEL
External finish
Power supply
Max. fuse size (time delay)
Min. ampacity
Fan motor
Airflow Lo—Me—Hi
Moisture removal
Sound level Lo-Me-Hi
Cond. drain connection O.D.
Dimensions
Weight
OUTDOOR UNIT MODEL
External finish
Power supply
Max. fuse size (time delay)
Min. ampacity
Fan motor
Compressor
Refrigerant control
Sound level
Dimensions
Weight
REMOTE CONTROLLER
Control voltage (by built-in transformer)
REFRIGERANT PIPING
Pipe size
Connection method
Between the indoor
& outdoor units
w1
w1
w1
Dry
Wet
W
D
H
Model
Winding resistance (at 68˚F) ½
W
D
H
Liquid
Gas
Indoor
Outdoor
Height difference
Piping length
Btu/h
W
V, phase, Hz
A
A
F.L.A
CFM
CFM
Pints/h
dB(A)
in.
in.
in.
in.
lbs
V, phase, Hz
A
A
F.L.A
R.L.A
L.R.A
dB(A)
in.
in.
in.
lbs
in.
in.
ft
ft
8,500
840
10.1 (10.2)
MS09NW
0.5
0.37
208-265-328
177-226-279
2.3
31-37-42
32-1/16
7-3/16
10-13/16
18
MU09NW
115, 1, 60
14
0.66
KH122WES
C-R 0.98 C-S 2.21
10
37
46
30-11/16
10-1/16
21-1/4
64
3/8
White
115, 1, 60
15
5/8
Munsell 5Y6.5/1
15
Capillary tube
Wireless type
12V DC
Not supplied (optional parts)
1/4
Flared
Flared
Max. 25
Max. 49
12,300/12,600
1,100/1,130
11.2/11.2 (11.3/11.3)
MS12NN
0.6
0.43
360-395-452
314-342-392
3.2
36-39-42
39-15/16
7-1/2
12-5/8
31
MU12NN
208/230, 1, 60
12
0.52
RH167NHDT
C-R 2.16 C-S 3.11
9
29
52
33-7/16
11/7/16
23-13/16
92
5/8
Cooling
Maximum
Minimum
Indoor intake air temperature
95˚FDB, 71˚FWB
67˚FDB, 57˚FWB
Outdoor intake air temperature
115˚FDB
67˚FDB
SPECIFICATIONS
When MS09NW indoor unit is operating with MUM18NW and MUM30NN outdoor unit connected.
(Please refer to the manual No.OB202 for MUM18NW and MUM30NN.)