Mitsumi electronic LGH-F1200RX3-E Air Conditioner User Manual


 
2
1. For connection of a remote controller (PZ-41SLB-E)
If the Lossnays operation is linked with the operation of an external device such as an air conditioner, the method of use will differ, so carry out
the appropriate operation in accordance with the following table. Also, please see the installation and users manual for the remote controller
(PZ-41SLB-E).
<If not connected to an external device>
2. For connection of a Mitsubishi Electric
Air-Conditioner Network System
(MELANS) or City Multi.
This is to be incorporated and used in the Mitsubishi Electric Air-
Conditioner Network System.
This is interlocked with the City Multi and operated by it.
Note
Remote controller PZ-41SLB-E cannot be used with this sys-
tem.
System diagram
LOSSNAY VENTILATE setting
Both fresh air supply and return air pass through the Lossnay core(s).
Resulting in full heat exchange. Lossnay ventilate setting is used for
cooling in the summer and heating in the winter period.
BY-PASS VENTILATE setting
The fresh air passes through the Lossnay core(s) and the return
room air is exhausted direct. Lossnay bypass ventilate is normally
operated during the spring/autumn months.
<If connected to an external device>
Example of System Function
If 2 remote controllers are used, the last
controller to be used has priority. (Last
Command)
Operation
Run using the remote
controller.
City Multi
indoor unit
Power
supply
A/Cs remote controller
Lossnay unit
LGH-**RX
3-E
M-NET transmission line
Interlocked to the City Multi indoor unit
Operation
If you would like to turn ON the Lossnay
alone while the external device is OFF,
operate it by the Lossnay remote control-
ler.
The fan speed is on High.
The ventilation mode is Ventilation Mode
Auto Select.
If an external device is
connected the On/Off
function of this device will
also control the Lossnay
operation.
Lossnay
Power Supply
Remote Controller
(Optional parts)
(PZ-41SLB-E)
Lossnay
Power Supply
External device
Remote Controller
(Optional parts)
(PZ-41SLB-E)
Power Supply
Operation switch for the external device
Lossnay
Power Supply
Power Supply
Operation switch for the external device
External device
AUTOMATIC VENTILATION setting
The automatic damper mode automatically provides the correct ven-
tilation for the conditions in the room. The following shows the effect
By-pass ventilation will have under various conditions.
Fresh air
Exhaust air
Lossnay core
Damper
Return air
Damper
Return air
Supply air
Supply air
Lossnay core
Exhaust air
Fresh air
Models LGH-F300, F470, F600RX3-E Model LGH-F1200RX3-E
Exhaust air
Fresh air
Lossnay core
Damper
Return air
Supply air
Exhaust air
Fresh air
Lossnay core
Damper
Return air
Supply air
Models LGH-F300, F470, F600RX3-E Model LGH-F1200RX3-E