Mitsumi electronic - U Air Conditioner User Manual


 
13
MUZ-A24 MUY-A24 MUZ-D MUY-D MUZ-FE18 MUZ-GA MUY-GA MUZ-GE24 MUY-GE24
POWER
SUPPLY
NOISE
FILTER
CIRCUIT
RESISTOR
RELAY
SMOOTHING
CAPACITOR
CURRENT
TRANSFORMER
COMPRESSOR
REACTOR
P
W
V
U
N
INTELLIGENT
POWER MODULE
POWER FACTOR
CORRECTION
MODULE
U
W
MS
3~
V
+
Function of main parts
NAME FUNCTION
INTELLIGENT POWER MODULE It supplies 3-phase AC power to compressor.
SMOOTHING CAPACITOR It stabilizes the DC voltage and supplies it to INTELLIGENT POWER MODULE.
CURRENT TRANSFORMER It measures the current of the compressor motor.
REACTOR
It recti es AC, controls its voltage and improves the power factor of power supply.
POWER FACTOR CORRECTION MODULE
RESISTOR
It absorbs the rush current not to run into the main power supply circuit when the
electricity turns ON.
RELAY
It keeps the RESISTOR, which restricts rush current, short-circuited while the
compressor is operating.
2-7-2. Outline of main power supply circuit
MUZ-A09/12/15/17 MUY-A15/17 MUZ-FD MUZ-FE09/12 MUZ-GE09/12/15/18 MUY-GE09/12/15/18
1. At the start of operation
Main power supply circuit is formed when RELAY is turned ON at COMPRESSOR startup.
To prevent rush current from running into the circuit when power supply is turned ON,
RESISTOR is placed in sub circuit.
2. At normal operation
When AC runs into POWER P.C. board, its external noise is eliminated in NOISE FILTER CIRCUIT.
After noise is eliminated from AC, it is recti ed to DC by DIODE MODULE 1.
DC voltage, to which AC has been recti ed by process , is stabilized by SMOOTHING CAPACITOR and supplied to IN-
TELLIGENT POWER MODULE.
DC voltage, which has been stabilized in process , is converted to 3-phase AC by INTELLIGENT POWER MODULE and
supplied to COMPRESSOR.
CURRENT TRANSFORMER, which is placed in the power supply circuit to COMPRESSOR, is used to measure the value
of phase current and locate the polar direction of rotor with algorithm. PWM (Pulse width modulation) controls impressed
voltage and frequency with those pieces of information.