Mitsumi electronic -1 Air Conditioner User Manual


 
14
3. Purpose of PAM adoption
PAM (Pulse Amplitude Modulation) has been adopted for the ef ciency improvement and the adaptation to IEC harmonic cur-
rent emission standard
Outline of simple partial switching method
In conventional inverter models, DIODE MODULE recti es AC voltage to DC voltage, SMOOTHING CAPACITOR makes its
DC waveform smooth, and INTELLIGENT POWER MODULE converts its DC voltage to imitated AC voltage again in order to
drive the compressor motor.
However, it has been difficult to meet IEC harmonic current emission standard by above circuit because harmonic gets
generated in the input current waveform and power factor gets down. The simple partial switching method with PAM, which
has been adopted this time, places and utilizes BOOSTER CHOPPER CIRCUIT before rectifying AC voltage in the general
passive-method converter circuit. As harmonic gets suppressed and the peak of waveform gets lower by adding BOOSTER
CHOPPER CIRCUIT as mentioned above and by synchronizing the timing of switching with the zero-cross point of waveform,
the input current waveform can be improved and the requirement of IEC harmonic current emission standard can be satis ed.
Since the switching synchronized with the zero cross point, this simple partial switching method has the feature of lower en-
ergy loss compared to active lter method. In addition, output and ef ciency is enhanced by combining with vector-controlled
inverter in order to boost the voltage of power supplied to INTELLIGENT POWER MODULE.
Input current waveform without PAM Input current waveform with PAM
Due to the time of no electricity;
• Power factor gets worse.
• Harmonic gets increased.
Input voltage
Energized time is short in
case L inductance is small.
No electricity runs into
diode module because the
voltage at both sides of smoothing
capacitor is higher than input voltage.
Input current
Owing to the increase of energized time;
• Power factor gets better.
• Harmonic gets suppressed.
Release of energy stored in L.
Peak gets down.
Energized time is
extended by
optimization
of L inductance.
Compulsory energizing
by switching.