Mitsubishi Electronics SRR25ZJ-S Air Conditioner User Manual


 
–14–
Airflow direction adjustment
PROGRAM TIMER operation
The timer operations of the combination of ON and OFF TIMER. Once this has been set the timer operations will be repeated at the same time every
day unless the ON/OFF button is pressed.
Example: When it is prefered to stop at 22:30, and then start operation at 8:00, near the
set temperature.
OFF TIMER operation setting
Set by the procedures on page 12. Set to
ON TIMER operation setting
Set by the procedures on page 13. Set to
Timer light (yellow) on the unit will light when the setting is completed.
The set time will be displayed on the remote control unit. The display will
change depending on the operational status.
How to cancel
Press the CANCEL button to turn off the timer display.
Changing of set time
Set a new time by using the OFF TIMER or ON TIMER button.
Comfort Start-up
In ON TIMER operation, the unit starts the operation a little earlier, so that the
room can approach optimum temperature at ON time. This is so called
“Comfort start-up”.
Mechanism
The room temperature is checked
60 minutes before the ON time.
Depending on the temperature at
that time, the operation starts 5 to
60 minutes before the timer is at
ON.
The function is available for both
COOL and HEAT operation
mode (including AUTO). It does
not work for DRY mode.
SLEEP TIMER
In COOL operation
(Stop) Operation starts
Check the room
temp. 60 mins.
before.
Set time
When SLEEP TIMER is selected, the set temperature is automatically
adjusted after a while, ensuring that the room is not too cold during cooling or
too warm during heating.
During cooling : The preset temperature is lowered by 1°C at the start of
SLEEP operation (when the timer is set). After that, the temperature goes
up by 1°C every an hour to become 1°C higher than the present
temperature.
During heating: The preset temperature is lowered by 1°C at the start of
SLEEP operation (when the timer is set). After that the temperature be-
comes 3°C lower in an hour and 6°C lower in two hours than the present
temperature.
(Operation)
Set temperature
With ON TIMER, the air conditioner starts running. Then,
with OFF TIMER, the air conditioner stops running.
With OFF TIMER, the air conditioner stops running. Then,
with ON TIMER, the air conditioner starts running.
Adjusting up/down air flow direction
Air flow direction adjustment can not be performed, although a display will be changed if
"AIR FLOW" button is pushed.
RJD012A200G_EN_001-022 4/21/14, 13:4314