Mitsubishi Electronics SRK507J-S Air Conditioner User Manual


 
-
27
-
'10 • SR-T-091D
(b) Floor standing type (SRF)
Models SRF25ZJX-S, 35ZJX-S, 50ZJX-S
Color Marks
Blue
BlackBK
Red
BL
RD
WhiteWH
YellowGreenYG
YellowYE
ColorMark
Heat exch. sensor
Humidity sensor
Fan motor
Room temp. sensor
Flap motor
Th1
Th2
Th3
Diode stackDS
FuseF
Connector
CNE-CNX2
FM
I
Terminal blockT
Damper motor
DM1
SM
1,2
1,2
Damper arm motor
Description
Item
VaristorVa
DM2
250V
F
G
3.15A
SN
Va
CNU
CNS
INTERFACE KIT
SC-BIKN-E
CNG
CNE
DISPLAY
WIRELESS RECEIVER
J
CNF
U
M
HEAT
1
3
4
5
6
BACK-UP SW
5
2
10
EXCHANGER
L
Th1
BOARD
CIRCUIT
PRINTED
CNX2
CNX1
M
M
M
M
5
5
5
5
5
5
5
5
RD
WH
RD
WH
BK
BL
YE
YG
BK
t
Th2
1
Th2
2
Th3
DM
1
DM
2
SM
1
SM
2
FM
I
DS
t
t
TO OUTDOOR UNIT
HEAT
EXCHANGER
1
2N
3
POWER WIRES
SIGNAL WIRE
1
2/N
3
Power source
1 phase 220 - 240 V 50Hz
T
AIR SELECTION SW
RWB000Z052