Mitsubishi Electronics SEH-1.6AR Air Conditioner User Manual


 
The Perfect Single or Multi Room Solution
The Perfect Multi-Room or Whole Home Solution
The Perfect Large Home Solution
Model SEH-1.6AR SEH-2AR SEH-2.5AR
Function cooling/heating cooling/heating cooling/heating
Nominal Capacity (watts) 4465/4800 6183/6640 7672/8015
Net Capacity (watts) 3,900/4,200 5,400/5,800 6,700/7,000
Indoor Components
Fan Coil Unit + LCD Control
Indoor Unit Air Flow (µs) 215 290 340
Sound Pressure Level
dB(A) low 30-35 high low 31-39 high low 32-43 high
Dimensions (mm) WxDxH 1,100x700x270 1,100x700x270 1,100x700x270
Horizontal Discharge
Outdoor Unit
Outdoor Unit Single ph, 50HZ 240V Single ph, 50Hz, 240V Single ph, 50Hz, 240V
Sound Pressure Level
dB(A) 50 52 51-53
Dimensions (mm) WxDxH 870x290x605 870x290x605 870x295x850
Model PEH-2.5EKA PEH-3EK[H]A PEH-4EK[H]SA PEH-5EK[H]SA PEH-6EKSB
Function Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating
Nominal Capacity (watts) 6,985/7,443 8,817/9,500 11,107/11,908 14,198/14,885 17,404/19,923
Net Capacity (watts) 6,100/6,500 7,700/8,300 9,700/10,400 12,400/13,000 15,200/17,400
Indoor Components
Indoor Unit Air Flow (µs)
450 450 560 700 1030
Sound Pressure Level
dB(A)
low 52-55 high low 52-55 high low 54-58 high low 54-58 high low 54-58 high
Dimensions (mm) WxDxH 785x690x428 785x690x428 1055x690x428 1255x690x428 1465x690x428
Horizontal Discharge
Outdoor Unit
Outdoor Unit single ph, 50Hz, 240V single/3ph, 50Hz, 240V 3ph, 50Hz, 415V 3ph, 50Hz, 415V 3ph, 50Hz, 415V
Sound Pressure Level dB(A)
52 52 54 55 56
Dimensions (mm)
WxDxH
870x295x850 870x295x850 870x295x1258 970x345x1258 970x345x1258
Model PEH 7 PEH 8 PEH 10 PEH 15 PEH 20
Function cooling/heating cooling/heating cooling/heating cooling/heating cooling/heating
Nominal Capacity (watts) 20,495/21,520 25,190/25,190 32,900/32,900 44,000/57,600 57,600/57,600
Net Capacity (watts) 17,900/18,800 22,000/22,000 28,800/28,800 35,200/44,000 46,000/57,600
Indoor Components
(Optional Controls)
Indoor Unit Air Flow (µs)
1000 1170 1500 2333 3000
Sound Pressure Level
dB(A)
54 high 56 high 59 high 61 high 62 high
Dimensions (mm)
WxDxH
1415x650x428 1415x650x428 1615x650x428 1690x865x706 1993x865x706
Horizontal Discharge
Outdoor Unit
Outdoor Unit 3ph, 50Hz, 415V 3ph, 50Hz, 415V 3ph, 50Hz, 415V 3ph, 50Hz, 415V 3ph, 50Hz, 415V
Sound Pressure Level dB(A)
65 65 65 69 69
Dimensions (mm)
WxDxH
14,00x700x980 14,00x700x980 14,00x700x980 1951X1080X1200 1951X1080X1200
Note 1: Net Capacity test conditions based on Australian Standards 1861 ‘Condition A’. Cooling DB 27°C WB 19°C, outdoor DB 35°C WB 24°C. Heating Indoor DB
21°C, Outdoor DB 7°C WB 6°C. Note 2: Sound Pressure Band based at 1 metre from the source. Note 3: Data based on indicated voltage 1ph-240V-50Hz and 3ph-
415V-50Hz. Note 4: Guaranteed operating range. Cooling operation -5°C to 46°C DB Heating operation -8.5°C DB to 21°C DB. Note 5: PEH 7, 8, 10 Warranty: 5 years
residential, 2 years commercial; PEH 15, 20 Warranty: 2 years commercial.
1
1
1
2
2
2
2
2
2
3
3
3