Mitsubishi Electronics S Air Conditioner User Manual


 
4-way Ceiling Cassette Type Specifications
HEAT PUMP
POWER INVERTER
Type
Indoor Unit
Outdoor Unit
Power Supply [V, Phase, Hz]
PLA-RP35AA
PUHZ-RP35VHA2
3.6
1.6 - 4.5
1.07
3.36
A
4.1
1.6 - 5.2
1.12
3.66
A
11 - 12 - 13 - 14
0
27 - 28 - 29 - 31
13 / -
16
/ -
12.7 / 6.35
50 / 30
-5 ~ +46
-11 ~ +21
PLA-RP50AA
PUHZ-RP50VHA2
5.0
2.3 - 5.6
1.55
3.23
A
6.0
2.5 - 7.3
1.62
3.70
A
14 - 15 - 16 - 18
0
28 - 29 - 31 - 33
13 / -
16 / -
12.7 / 6.35
50 / 30
-5 ~ +46
-11 ~ +21
PLA-RP60AA
PUHZ-RP60VHA2
6.0
2.7 - 6.7
1.65
3.64
A
7.0
2.8 - 8.2
1.85
3.78
A
14 - 15 - 16 - 18
0
28 - 29 - 31 - 33
19 / -
25 / -
15.88 / 9.52
50 / 30
-5 ~ +46
-11 ~ +21
PLA-RP71AA
PUHZ-RP71VHA2
7.1
3.3 - 8.1
1.97
3.60
A
8.0
3.5 - 10.2
2.34
3.42
B
15 - 16 - 18 - 20
0
28 - 30 - 32 - 34
19 / -
25 / -
15.88 / 9.52
50 / 30
-5
~ +46
-11 ~ +21
PLA-RP100AA2
PUHZ-RP100V(Y)HA2
10.0
4.9 - 11.4
3.02
3.31
A
11.2
4.5 - 14.0
3.02
3.61
A
19 - 21 - 23 - 29
0
33 - 36 - 39 - 41
121 / 135
49(46) - 51
28 / 13
32 / 16
15.88 / 9.52
75 / 30
-5 ~ +46
-20 ~ +21
PLA-RP125AA2
PUHZ-RP125V(Y)HA2
12.5
5.5 - 14.0
3.87
3.23
A
14.0
5.0 - 16.0
3.88
3.61
A
298 (Panel : 30)
840 (Panel : 950)
840 (Panel : 950)
32 (panel:5)
0
37 - 40 - 43 - 45
1,350 x 950 x 330(+30)
100
50(47) - 52
28 / 13
32 / 16
15.88 / 9.52
75 / 30
-5 ~ +46
-20 ~ +21
PLA-RP140AA2
PUHZ-RP140V(Y)HA2
14.0
5.5 - 15.3
4.65
3.01
B
16.0
5.0 - 18.0
4.69
3.41
B
0
37 - 40 - 43 - 45
50(47) - 52
29.5 / 13
40 / 16
15.88 / 9.52
75 / 30
-5 ~ +46
-20 ~ +21
Inverter Heat Pump
PLZ-RP
series
Cooling
Heating
Indoor
Outdoor
Breaker Size
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
Capacity
Total Input
COP
Dimensions
Weight
Air Volume (Lo-Mi2-Mi1-Hi)
External Static Pressure
Sound Level (Lo-Mi2-Mi1-Hi)
Dimensions
Weight
Air Volume
Sound Level
Max. Running Current
Diameter
Max. Length / Height
Rated
Min - Max
Rated
EEL Rank
Rated
Min - Max
Rated
EEL Rank
Height
Width
Depth
H x W x D
1 phase / 3 phase
Cool(Silent) - Heat
1 phase / 3 phase
1 phase / 3 phase
Gas / Liquid (
Cooling*
Heating
* With the optional air protect guide, the operation at -15
o
C outdoor temperature is possible.
kW
kW
kW
kW
kW
kW
mm
mm
mm
kg
m
3
/min
Pa
dB(A)
mm
kg
m
3
/min
dB(A)
A
A
mm
m
o
C
o
C
VHA:230V, 1 phase, 50Hz
YHA:400V, 3 phase, 50Hz
VHA:230V, 1 phase, 50Hz
258 (Panel : 30)
840 (Panel : 950)
840 (Panel : 950)
24 (panel:5)
24 - 25 - 27 - 30
116 / 130
600 x 800 x 330(+23)
45 / -
35
44(41) - 46
943 x 950 x 330(+30)
75 / -
55
47(44) - 48
44
4 notch
ACO
Anti mold
DP
Hot Start
Quiet
Fresh Air Intake
Self
Diagnosis
High efficiency
Optional
Check!
Handy
corner pocket
Drain
Lift UP
RP100 140
75m
RP100 140
Heating at
-20˚C
COMPO
Auto Restart
Easy
Maintenance
Weekly
Timer
Lossnay
connection
Group
Control
M-NET
connection
Optional
High
Ceiling
72
patterns
SWING
Air flow
IN/OUT
Power Supply
Optional
Optional
Exising
Wiring Reuse
AUTO
VANE
Gas Volume
Check
Indoor Unit
PUHZ-RP35/50 PUHZ-RP60/71 PUHZ-RP100/125/140
Outdoor Unit
Remote Controller
series
43
P