Mitsubishi Electronics PUHY-P264 Air Conditioner User Manual


 
[ V Electrical Wiring Diagram ]
- 77 -
HWE08040 GB
(3) PUHY-P72, P96,P120YHMU-A
HIC bypass,Controls refrigerant
flow in HIC circuit
Ground
G
GG
L3
L1
L2
Power Source
3~
60Hz
460V
Transformer Box
purple
1
2
3
4
CN06
T02
(Transformer)
CNTR2
4
3
2
1
CN07
1
2
3
4
5
6
T03
(Transformer)
CNTR3
5
6
2
4
3
1
460V
460V
purple
*7
1
21S4b
21S4c
CN501
X01
1
3
X09
3
6
CN508
black
Unit address
setting
CN504
green
CT12
C31
C33
CN5
red
D1
R5
Z5
1
SV9
CNTR1
12
L1L2L2
3
L3
45678
R631
white
TH2
white
red
black
black
white
red
F4
600V
3A F
C8
F5
600V
3A F
red
CNIT
yellow
CNS2
1
1
LED1
Display
setting
CN51
12V
Function
setting
SW1
10
1
CN212
CNTYP4
green
F4
AC250V
6.3A T
R4
F3
F1
Z4
R2
F2
*3
3
2
Compressor ON/OFF output
Error detection output
CN201
Z25
1
4
1
1
1
TH3
Z3
3
Z2
U
ONOFF
SW2
10
1
SWU2
LED1
C4
C35
C37
R31
R33
R30
ON
SW3
10
Control Board
TH7
CN40
63HS1
CN41
TH6
TH4
3
2
2
2
1
SW5
LED3:Lit when powered
1
3
4
R32
2
Z1
1
DSA
C10
R34 R35
LEV1
LEV2a
C36
3
C34
SC-V
CT22
SC-U
V
1
CN4
blue
red
1
M
1
LEV2b
1
LED3:CPU in
operation
black
4
1
CNTYP2
black
3
6
yellow
CN3K
*3
3
M
C3
TB21
C1
R3
3
M
CN1A
5
U
CN2
blue
CN3N
5
6
C7
U
44
R1
CN21
blue
TB1
1
CN1B
3
3
TB7 Power
selecting
connector
CN102
CNVDC
THBOX
3
2
1
IPM
2
21
U
4
TP1
W
L3
DCL
V
black
72C
white
red
3
3
21
ON
OFF
12
M-NET power
supply circuit
123
C6
M-NET Board
12
1
Power failure
detection circuit
1
CNAC2
black
CN502
5
Indoor/Outdoor
transmission
cable
INV Board
red
3
CNT01
TB23
L2L1
U
4
1
ON
1
2
1's
digit
THHS
1
CNIT
red
S
2
1
1
CN990
1
3
W
TB3
10's
digit
OFF
LED2:CPU in operation
5
2
CNS2
yellow
TB7
1
CNDC
pink
M1
2
2
red
6
MS
3~
1
1
C100
*5
3
3
U
1
4
LED1:Power supply to
Indoor/Outdoor
transmission line
ZNR01
M2
32
M1
black
Central control
transmission
cable
*6
SC-L1
1
4
C2
C9
ON
C5
OFF
FT-N
R5
M
3~
Motor
(Compressor)
CN5V
yellow
5
2
3
3
3
red
CN3S
1
1
CN04
red
1
CN2
2
3
CN4
X05
2
2
Fan motor
(Heat exchanger)
SC-P2
P
1
CN211
CN202
red
TH5
N
CN1
M2
2
TP2
LED1
:
Normal operation(Lit)
/ Error(Blink)
2
CN503
blue
5
X04
4
*4
SC-W
U
C32
SC-L3
CH11
CN506
1
2
CN72
red
3
P
63H1
CN801
yellow
1
2
CN332
blue
F1,F2,F3
AC250V
6.3A T
21
OFF
SW4
10
1
CNT02
11
CN3D
432
1
21
CPU power
supply circuit
CNAC
red
2
1
F01
AC250V
3.15A T
1
CN507
red
ONOFF
10
SWU1
white
CN213
red
SC-L2
3
Z24
7
4
3 21122
7
1
2
CN5
1
CN4
red
CNINV
3
4
R630
1
1
C630
3
CN22
red
C631
5
F01
DC700V
4A T
1
CNTYP5
green
4
LED2:Error
21S4a
1
LED1:Normal
operation
2
3
2
U
X02
X03
CN18V
blue
5
1
7
CN4
3
CN6
2
IGBT
4
SC-P1
FT-P
black
C30
red
Diode
Bridge
CT3
72C
C1
CN2
CNTYP
black
R1
black
TB22
6
3
RSH1
CN102
3
R6
C17
1
1
1
FAN Board
63LS
ZNR1
U
L
3
Noise
Filter
SV5b
X08
3
1
CN6
yellow
red
SV5c
X07
3
5
6
CN LVA
CNLVB
red
CNLVC
red
1
2
3
4
5
6
white
black
SV1a
6
5
4
3
2
1
6
5
4
3
2
2
1
L1 L2 L3
1
CN215
black
For opening/closing the bypass
circuit
Terminal
block
Central control transmission
cable
Indoor/Outdoor transmission
cable
Power supply
Function setting connector
IGBT temperature
OA temperature
ACC inlet pipe temperature
Discharge pipe temperature
Thermistor
Control box internal temperature
SV9
TB1
TB3
TB7
TH3
TH4
TH5
TH6
TH7
THHS
Z24,25
THBOX
TH2
Subcool bypass outlet
temperature
DC reactor
Linear
expansion
valve
Crankcase heater(for heating the compressor)
Current sensor(AC)
Magnetic relay(inverter main circuit)
Low pressure
Discharge pressure
High pressure protection for the
outdoor unit
Pressure
switch
Cooling/Heating switching
Pressure
sensor
Explanation
4-way valve
Heat exchanger capacity control
For opening/closing the bypass
circuit under the O/S
Solenoid
valve
Pressure control,Refrigerant flow
rate control
DCL
LEV1
CT12,22,3
CH11
21S4b,c
72C
63LS
63HS1
63H1
<Symbol explanation>
Symbol
21S4a
LEV2a,b
SV1a
SV5b,c
Outdoor unit heat exchanger
capacity control
Pipe temperature
Subcooled liquid refrigerant
temperature
*1.Single-dotted lines indicate wiring not supplied with the unit.
*2.Dot-dash lines indicate the control box boundaries.
*3.Refer to the Data book for connecting input/output signal connectors.
*4.Daisy-chain terminals (TB3) on the outdoor units in the
same refrigerant system together.
*5.Faston terminals have a locking function.
Make sure the terminals are securely locked
in place after insertion. Press the tab
on the terminals to removed them.
*6.Control box houses high-voltage parts.
Before inspecting the inside of the
control box,turn off the power,keep
the unit off for at least 10 minutes,
and confirm that the voltage between
FT-P and FT-N on INV Board has dropped
to DC20V or less.
*7.Difference of appliance
Model name
Appliance
*7 do not exist
*7 exist
P120
P72/P96
+-
+
2
++
++
++
++
1