Mitsubishi Electronics PKH18FL Air Conditioner User Manual


 
35
<How to operate>
To change the air flow direction, press VANE ( ) button.
(1) COOL/DRY operation
At the start-up of COOL or DRY operation, the discharge direction in automatically set to 10°. After, it can be changed to
another direction with VANE ( ) button on the remote controller.
<Auto return>
When discharge 60° or 70° continues for 1 hour with the fan speed at LOW, the discharge direction turns to the horizontal
discharge automatically.
After that, 60° or 70° is available by setting with the remote controller, and it continues for 1 hour.
If the discharge direction changes from 60° or 70°, the direction returns to the horizontal discharge when 1 hour has
passed since the discharge 60° started.
If the discharge direction changes from 60° (or 70°) to the horizontal discharge, the 1-hour timer to return the horizontal
discharge is cancelled.
(2) HEAT operation
At the start-up of HEAT operation, discharge direction depends on the setting of the last operation.
After, it can be changed to another direction with VANE ( ) button. The discharge direction shifts to 10° regardless of
the remote controller settings under any of the following conditions.
Thermostat OFF
Defrosting
Indoor fan speed LOW in hot adjustment
Available in COOL operation with fan speed on HIGH or
in HEAT operation.
Unavailable in DRY operation.
If fan speed changes from LOW to HIGH during 30°
downward discharge in COOL mode, the direction auto-
matically changes to 10°.
10°
1
30° downward
2
60° downward
3
70° downward
4
SWING5
2-5 Auto vane control
<Remote controller display>
Changes by pressing the AIR DISCHARGE button.
12
3
4
5
10˚
30˚
60˚
70˚
SWING
ON/OFF TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESETSET CLOCK
SWING
FAN
˚F
AM
AUTO
OC276-A-2.qxp 03.11.25 9:06 AM Page 35