Mitsubishi Electronics PFFY-NEMU-A Air Conditioner User Manual


 
6
GB
D
F
INL
E
PGRRUTR
3
2
E
C
A
1
B
4
687
* The range of room temperature display is 8 °C [46 °F] - 39 °C [102 °F]. Outside
this range, the display flashes either 8 °C [46 °F] - 39 °C [102 °F] to inform you
if the room temperature is lower or higher than the displayed temperature.
3.4. Fan speed adjustment
To change fan speed
Every time you press the 6 [fan speed] button once, it switches from the low-
speed to high-speed settings successively.
In the electronics dry operation, the indoor fan automatically turns to low-speed
operation. Switching of fan speed is impossible. (Only the display on the remote
controller changes.)
* Every time the fan speed adjustment button is once pressed, the fan speed is
changed.
[PDFY-40 48NMU-A, PFFY-NEMU-A, PFFY-NRMU-A]
Fan speed : 2 stages
Display:
(Low) (High)
[PDFY-10-32NMU-A]
Fan speed : 4 stages
Display:
(Low) (Mid2) (Mid1) (High)
3.5. Adjustment of up/down airflow direction
To change the up/down airflow direction
PFFY-NEMU-A
While pulling the blowout grill out toward you, raise the rear, remove it, change the
direction, and set it in place.
Caution:
Avoid putting your hand into the air outlet of the indoor unit any more than
necessary during operation. If you get your hands caught in the metal parts
when adjusting the airflow-direction-adjustment board and blowout grill, or
nip them in the autovane, there is a risk of injury and failure.
3.6. Time setting
Set the current time after turning ON the power of the air conditioner or after
restoration from a power failure.
It can be set regardless of the operation of the indoor unit.
During the time operation, the time-setting button becomes void, disabling time
setting.
1. Press the
44
44
4 [time selection] button and bring up the
AA
AA
A current time
display
Every time it is pressed, the display changes.
Caution:
When the current time is not yet set, the CLOCK (current time) display
flashes, disabling the setting of timer operation.
2. Set the current time by pressing the
44
44
4
or button
The time cannot be set while the C
is displayed.
While the A CLOCK time is displayed, press the time setting 4
/
buttons and set the time.
The setting advances one minute every time the 4
button is pressed
once, and retrogresses one minute every time the 4
button is pressed
once.
When respective 4 / buttons are pressed continuously, the time
display goes fast forward. It advances in the order of 1 minute unit - 10 minute
unit - one hour unit.
About 10 seconds after the button operation has been completed, the C cur-
rent time and A CLOCK displays disappear.
Caution:
Remote controller is equipped with a simplified clock with a precision of
about + or - one minute per month.
The time must be readjusted (reset) every time the air conditioner is sub-
jected to a power stop of the air conditioner or a power failure.
For fan
Press the
33
33
3 [selecting operation] button and bring up the FAN display.
The fan operation functions to circulate the air in the room.
The temperature of the room cannot be set by fan operation.
Caution:
Never expose your body directly to cool air for a long time. Excessive expo-
sure to cool air is bad for your health, and should therefore be avoided.
Dry operation
The dry is a microcomputer-controlled dehumidifying operation which controls ex-
cessive air-cooling according to the room temperature of your choice. (Not usable
for heating.)
1. Until reaching room temperature of your choice
The compressor and indoor fan function is linked motion according to the change
of the room temperature and automatically repeat ON/OFF.
2. When reaching room temperature of your choice
Both the compressor and indoor fan stop.
When stop continues for 10 minutes, the compressor and indoor fan are oper-
ated for 3 minutes to keep the humidity low.
For heating
Press the
33
33
3 [selecting operation] button to bring up the HEAT display.
Regarding displays during heating operation DEFROST
Displayed only during the defrosting operation.
STAND BY
Displayed from the start of heating operation until the moment warm air blows out.
Caution:
When the air conditioner is used together with burners, thoroughly ven-
tilate the area. Insufficient ventilation can result in accidents due to oxy-
gen deficiency.
Never place a burner at a place where it is exposed to the airflow from the
air conditioner.
Doing so can result in imperfect combustion of the burner.
The microcomputer functions in the following cases:
Air does not blow out when heating starts.
- To prevent any cool air from escaping, the indoor fan is gradually switched in
sequence from faint airflow/weak airflow/set airflow according to the tem-
perature rise of the blown out air. Wait a moment until the airflow comes out
naturally.
The fan is not moving at the set speed.
- In some models, the system switches over to faint airflow when the tempera-
ture of the room reaches the set temperature. In other cases, it stops to
prevent any cool air from escaping during the defrosting operation.
Air flows out even if operation is stopped.
- Approximately 1 minute after the stop of operation, the indoor fan sometimes
rotates to eliminate extra heat generated by the electric heater, etc. The fan
speed comes to low or high.
3.3. Room temperature adjustment
To change room temperature
Press the
11
11
1 [room temperature adjustment] button and set the room tem-
perature of your choice.
Pressing
or once changes the setting by 1 °C [2 °F].
If the pressing is continued, the setting continues to change by 1 °C [2 °F].
Indoor temperature can be set within the following range.
Cooling/dry:19 °C [67 °F] 30 °C [87 °F]
Heating: 17 °C [63 °F] 28 °C [83 °F]
It is impossible to set the room temperature by the air-blow operation.
CLOCK
current
time
(no display)
timer end
time
AUTO
OFF
timer start
time
AUTO
ON