Mitsubishi Electronics PE-10MYC Air Conditioner User Manual


 
- 112 -
Thyristor module
(SCRM)
<Judgment Method> Measure the resistance between each of the SCRM pins and judge if there is a failure or not by the
resulting values.
<Judgment Values 1> Check between G and K.
Use the smallest resistance range on the tester.
Judgment Value: 1.5 ohm 80 ohm
<Judgment Values 2>
<External View>
<Internal Circuit Diagrams>
Check between AK1 and AK2.
Use the greatest resistance range on the tester.
Judgment Value: 60 kilo-ohm ohm
K
AK1
AK1
AK1 AK1
AK2
AK2
AK2 AK2
GKGKG
GK GK GK
K
K
AK1
AK2
G
G
K
K
AK1
AK2
G
G
G
K
G
K