Mitsubishi Electronics MXZ-4B36NA Air Conditioner User Manual


 
9
No.
RoHS
Parts No. Parts Name
Symbol
in Wiring
Diagram
Q'ty/unit
Remakes
MXZ-
3B24NA
MXZ-
3B30NA
MXZ-
4B36NA
1 G M21 L2V 501 PROPELLER 1 1 1
2 G T2W 9T9 301 OUTDOOR FAN MOTOR MF 1 1 1 RC0J77-
3 G M21 0A1 440 POWER BOARD 1 1 1
Including heat sink and RT64
4
G T2W 9T9 451
ELECTRONIC CONTROL P.C. BOARD
1
G T2W 9T8 451
ELECTRONIC CONTROL P.C. BOARD
1
G T2W 9T7 451
ELECTRONIC CONTROL P.C. BOARD
1
5 G M21 9T7 337 REACTOR L 1 1 1 20 A 500 μH
6 G M21 0A0 424 NOISE FILTER P.C. BOARD 1 1 1
7 G T2W 0A2 376 TERMINAL BLOCK TB2~5 3 3 4 Indoor unit connecting
8 G T2W L7V 377 TERMINAL BLOCK TB1 1 1 1 Power supply
9 G T2W L7V 398 R.V. COIL 21S4 1 1 1
10 G M21 L2V 308 THERMISTOR SET
RT61,62,68
111
DEFROST, DISCHARGE,
OUTDOOR HEAT EXCHANGER
11 G M21 0A2 309
AMBIENT TEMPERATURE THERMISTOR
RT65 1 1 1
MXZ-3B24NA MXZ-3B30NA MXZ-4B36NA
1-4. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
RoHS PARTS LIST (RoHS compliant)