Mitsubishi Electronics MUZ-GE60VA Air Conditioner User Manual


 
30
ADDITIONAL REFRIGERANT CHARGE (R410A: g)
Model
Outdoor unit
precharged
Refrigerant piping length (one way)
5 m 6 m 7 m 8 m 9 m 10 m 11 m 12 m 13 m 14 m 15 m 20 m
MUZ-GE25VA
MUZ-GE25VAD
MUZ-GE33VA
MUZ-GE35VA
800
0 0 0 30 60 90 120 150 180 210 240 390
MUZGE35VA2
MUZGE35VAD
MUZ-GE42VA
MUZ-GE42VAD
1,150
Calculation: X g = 30 g/m × (Refrigerant piping length (m) - 7)
Model
Outdoor unit
precharged
Refrigerant piping length (one way)
7 m 10 m 15 m 20 m 25 m 30 m
MUZ-GE50VA
MUZ-GE50VA2
MUZ-GE50VAD
1,550 0 60 160 260 360 460
Calculation: X g = 20 g/m × (Refrigerant piping length (m) – 7)
Model
Outdoor unit
precharged
Refrigerant piping length (one way)
7 m 10 m 15 m 20 m 25 m 30 m
MUZ-GE60VA
MUZ-GE60VAD
1,550 0 0 100 200 300 400
Calculation: X g = 20 g/m × (Refrigerant piping length (m) – 10)
Model
Outdoor unit
precharged
Refrigerant piping length (one way)
7 m 10 m 15 m 20 m 25 m 30 m
MUZ-GE71VA
MUZ-GE71VAD
MUZ-GE80VA
MUZ-GE80VA2
MUZ-GE80VAD
1,900 0 0 275 550 825 1,100
Calculation: X g = 55 g/m × (Refrigerant piping length (m) – 10)
NOTE: Refrigerant piping exceeding 7 m (MUZ-GE25/33/35/42/50) or 10 m (MUZ-GE60/71/80) requires additional
refrigerant charge according to the calculation.