Mitsubishi Electronics MSZ-A12NA Air Conditioner User Manual


 
En-5
• OPERATING INSTRUCTIONS •
Emergency operation
When the remote controller cannot be used...
Emergency operation can be activated by pressing the emergency operation
switch (E.O.SW) on the indoor unit.
Each time the E.O.SW is pressed, the operation
changes in the following order:
1
Press
to start the operation.
2
Press to select operation mode. Each press
changes mode in the following order:
3
Press or to set the temperature.
Each press raises or lowers the temperature by 1°F
(1°C).
Press to stop the operation.
• The same setting is selected the next time by simply pressing
.
SELECTING OPERATION MODES
Operation indicator lamp
Emergency COOL
Stop
Note:
The first 30 minutes of operation is test run. Temperature
control does not work, and fan speed is set to High.
WASH
reset
E.O.
SW
Set temperature : 75°F
(24°C)
Fan speed : Medium
Horizontal vane : Auto
(AUTO)
(COOL)
(DRY)
(HEAT)
Operation indicator lamp
The operation indicator lamp shows the operation state of the unit.
Indication Operation state Room temperature
The unit is operating to reach the set
temperature
About 4°F (2°C) or
more away from set
temperature
The room temperature is approach-
ing the set temperature
About 2 to 4°F (1 to
2°C) from set tem-
perature
Standby mode (only during multi
system operation)
Lighted Blinking Not lighted
AUTO mode (Auto changeover)
The unit selects the operation mode according to the difference between the
room temperature and the set temperature. During AUTO mode, the unit
changes mode (COOL
HEAT) when the room temperature is 4°F (2°C)
away from the set temperature for more than 15 minutes.
Note:
• During multi system operation, the unit may not be able to switch
operation mode between COOL and HEAT. In this case, the indoor unit
becomes standby mode.
• Auto Mode is not recommended if this indoor unit is connected to a
MXZ type outdoor unit.
COOL mode
Enjoy cool air at your desired temperature.
Do not operate COOL mode at low outside temperature
(less than 14°F [-10°C]).
Water condensed in the unit may drip and wet or damage furniture, etc.
DRY mode
Dehumidify your room. The room may be cooled slightly.
Temperature cannot be set during DRY mode.
HEAT mode
Enjoy warm air at your desired temperature.
Emergency HEAT
Auto restart function
If a power failure occurs or the main power is turned off during operation, “Auto
restart function” automatically starts operation in the same mode as the one set
with the remote controller just before the shutoff of the main power. When
timer is set, timer setting is cancelled and the unit starts operation when power
is resumed.
If you do not want to use this function, please consult the service repre-
sentative because the setting of the unit needs to be changed.
Multi system operation
Two or more indoor units can be operated by one outdoor unit. When several
indoor units are operated simultaneously, cooling and heating operations cannot
be done at the same time. When COOL is selected with one unit and HEAT with
another or vice versa, the unit operated later becomes standby mode.