Mitsubishi Electronics MS-SD24VC Air Conditioner User Manual


 
En-9
• OPERATING INSTRUCTIONS •
Installation place
Avoid installing the air conditioner in the following places.
Where there is much machine oil.
Salty places such as the seaside.
• Where sul de gas is generated such as a hot spring.
Where oil is splashed or where the area is lled with oily smoke.
Where there is high-frequency or wireless equipment.
Where the air from the outdoor unit air outlet is blocked.
Where the operation sound or air from the outdoor unit does not bother the
house next door.
Electrical work
Provide an exclusive circuit for the power supply of the air conditioner.
Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
INSTALLATION PLACE AND
ELECTRICAL WORK
SPECIFICATIONS
To prevent the effects
of a uorescent lamp,
keep as far apart as
possible.
wall, etc.
Inverter-type
uorescent lamp
Keep a space to
prevent the pic-
ture distortion or
the noise.
1 m
or more
Radio
100 mm or
more
Well-
ventilated dry
place
200/500 mm
or more
TV
Cordless
phone or
Portable
phone
3 m or
more
1 m
or more
The installation location of the outdoor unit should
be at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
the antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours. Page 4
This dries the inside of the unit.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air lter. Page 7
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the earth is connected correctly.
WHEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
Model MS-SFD18VC MS-SD24VC
Dimensions
H × W × D (mm)
Indoor 325 × 1100 × 258 325 × 1100 × 258
Outdoor 550 × 800 × 285 850 × 840 × 330
Weight (kg)
Indoor 16 16
Outdoor 34
65
EER
3.23 3.23
Note:
1. Rating condition
Cooling — Indoor: 27°C DB, 19°C WB
Outdoor: 35°C DB, 24°C WB
2. Guaranteed operating range
Indoor Outdoor
Upper limit
32°C DB
23°C WB
43°C DB
Lower limit
21°C DB
15°C WB
21°C DB
Environment care
Mitsubishi Electric Air conditioner has been designed environment-friendly. The plastic composition can be used as recycle part.
For the optimum ef ciency and energy saving, users are recommended to operate air conditioners as following suggestion.
Turn off air conditioner in case of not in use.
Turn off ventilator in case of not in use.
The set temperature should not be set lower than 25°C.
The cleaning of condensing coil should be performed at least every 3 months.
The cleaning of air cleaning lter should be performed in the period described in this manual.
(SFD18/SD24)