Mitsubishi Electronics MSH-09NV Air Conditioner User Manual


 
9
Capacity
Electrical data
Compressor
Indoor
fan motor
Outdoor
fan motor
Dimensions
Weight
Special remarks
Model
Function
Power supply
Coefficient of performance(C.O.P)
Capacity
Dehumidification
Air flow
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Compressor motor current
Fan motor current
Model
Output
Winding resistance(at20:)
Model
Winding resistance(at20:)
Model
Winding resistance(at20:)
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Air direction
Sound level
(Hi)
Fan speed
(Hi)
Fan speed
regulator
Refrigerant filling capacity(R-22)
Thermistor
Width
Height
Depth
Width
Height
Depth
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
RT11(at25:)
RT12(at25:)
RT61(at0:)
kW
R/h
K /h
A
A
W
A(kW)
%
A
A
A
W
"
"
"
mm
mm
mm
mm
mm
mm
kg
kg
dB
dB
rpm
rpm
kg
k"
k"
k"
MSH-07NV- (INDOOR UNIT)
Cooling Heating
Single phase,220-240V,50Hz
— —
492
10
0.17
35
94-86
0.17
RC4V19-AA
WHT-BLK292 BLK-RED324
815
275
183
8
5
37
1,100
4
10
10
MSH-09NV- (INDOOR UNIT)
Cooling Heating
Single phase,220-240V,50Hz
— —
492
10
0.17
35
94-86
0.17
RC4V19-AA
WHT-BLK292 BLK-RED324
815
275
183
8
5
37
1,100
4
10
10
E1 E2 E1 E2
Please refer to Service manual OB185 for capacity.
NOTE:Test conditions
Cooling : Indoor DB27°C / WB19°C
Outdoor DB35°C / WB24°C
Heating : Indoor DB20°C /WB15.5°C
Outdoor DB 7°C / WB 6°C
Refer to the Service Manual OB185 when MSH-07/09/12NV- , MSH-07/09/12/18NV- , and MSH-18NV- are
connected with MXZ-32NV- as multi system units.
E1
E3E2E1
OB207t-1qxp 25/9/97 8:51 PM Page 9