AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT
AIR FLOW velocity and direction can be selected as required.
To change the AIR FLOW velocity, press the
FAN
button.
Each time the button is pressed, the fan speed is changed in sequence:
(Low) (Med.) (High) (AUTO)
Use the
(High) notch to cool/heat the room more.
If the operating sound of the air conditioner disturbs your sleep, use the
(Low) notch.
To change the AIR FLOW blowing direction vertically, press the
VANE
button.
Each time the button is pressed, the angle of the horizontal vane is changed in
sequence: 1 2 3 4 5
(SWING) (AUTO)
SWING OPERATION
Use the swing operation for the air flow to reach all corners of the room.
Recommended horizontal vane range
Use the
(AUTO) position usually.
Use position 1 or 2 in the COOL or DRY mode and use
positions 3 to 5 in the HEAT mode when adjusting to
your requirements.
NOTE:
In the cooling operation, when the air conditioner is operated with setting the horizontal vane to 4 or 5 for 1 hour, the
AIR FLOW direction is automatically set to horizontal to prevent condensed water from dropping.
Adjust the vertical AIR FLOW direction using the remote controller. If the horizontal vane is moved manually, it may
cause trouble.
In the heating operation, if the air flow temperature is too low or when defrosting is being done, the horizontal vane
position is set to position 1.
ON/OFF
FAN
TOO
WARM
TOO
COOL
VANE
MODE
ECONO COOL
STOP
START
HR.
MIN.
AMPM
CLOCK
˚C
AMPM
I FEEL
COOL
DRY
AUTO
HEAT
RESET CLOCK
12345
To change the horizontal direction of the AIR FLOW
For the ceiling suspended unit
Change the direction of the vertical vane manually.
For the floor standing unit
Change the direction of the vertical vane manually.
Adjust the vane before operation starts.
Since the horizontal vane moves automatically, your fingers may be caught.
When the air flow temperature
is too low, the air is blown out
horizontally.
When the air flow temperature
rises, the air is blown out down-
wards.
AUTO AIR FLOW DIRECTION CONTROL OPERATION
When the AUTO mode is selected with the
VANE
button, the position of the horizontal vane is automatically set to corre-
spond to the operation mode for effective operation.
For the floor standing unit
(1) COOL, DRY (2) HEAT
For the ceiling suspended unit
(1) COOL, DRY (2) HEAT
The air is blown out horizontally.
The air is blown out upwards. When the air flow temperature
rises, the air is blown out hori-
zontally.
When the air flow temperature is
too low, the air is blown out up-
wards.
COOL
DRY
HEAT
NOTE:
When the operation mode changes in
(AUTO) mode, the horizontal vane is automatically changed to the
position in each mode.