3-2 Checking the Operation Condition
When you login correctly using the Login Screen, the screen used to monitor the operation conditions of air
conditioner and general equipment and hot water supply groups will appear. If you wish to operate, click the
group icon to switch to the operation screen.
Note: The operation condition display will not update automatically. If you wish to view the very latest condition, click [Update] on
each screen.
Item Description
Update to most recent
condition
Click [Update] to ensure the displayed items reflect the most recent operation condition.
Batch Operation Click [Batch Operation] if you want to perform an operation on all groups at once.
Group name Group names are displayed.
Group icon
The operation condition is indicated by the icon that is displayed. When you point to a group icon
with the mouse cursor, the group name is displayed. To switch to the operation screen, click on
the icon. The icons used to indicate the operation condition are shown below.
(1) Air conditioner group operation condition
Batch operation
Click to perform an operation
on all groups at once.
Update to most recent
condition
Click to update the screen so
that the most recent condition is
shown.
Group icons
These icons are used to
indicate the operation condition
of an air conditioner or a
general equipment group.
Switch to the operation screen
by clicking the icon.
Set temperature display
The set temperature is
displayed here.
Room temperature displa
y
The temperature of the
indoor unit’s intake is
displayed here.
Operation mode display
The operation mode is
displayed here.
Group name
Group names are displayed.
ON OFF Error Filter sign
Interlocked
ventilator ON
Interlocked
ventilator OFF
Schedule set Energy saving
Setback ON
Note: Other than 4-aiflow icons, 2-airflow or ceiling-suspended icons are also available. Select the
icon type on Initial Setting Web.
Note: If a given LOSSNAY unit is interlocked with multiple indoor unit groups, the LOSSNAY unit
may be in operation even when the display shows that the unit is stopped.
Note: When setting ventilation interlock with Mr. Slim units, the air conditioning and interlocked
ventilation icon will display ON even when the interlocked LOSSNAY is operating by itself.
(This will occur when used with the following M-NET
adapter:PAC-SF48/50/60/70/80/81MA-E)
Note: When connecting multiple AG-150A controllers by connecting an Expansion Controller to the
system, “Schedule set,” “Energy saving,” and “Setback ON” will be displayed only on the
AG-150A controller that is executing these functions.