Mitsubishi Electronics A12 Air Conditioner User Manual


 
7
Electrical work
Provide an exclusive circuit for power supply of the air conditioner.
Be sure to observe the breaker capacity.
Warning:
The customer should not install this unit. If the unit is installed incorrectly, fire, electric shock, injury due to a falling unit, water leakage, etc.
may result.
Do not connect using branched outlet or an extension cord, and do not attach many loads to one electric outlet.
A fire or electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.
Caution:
Apply grounding
Do not connect a grounding wire to a gas pipe, water pipe, lightning rod or ground wire of a telephone.
If a grounding is incorrect, it may cause an electric shock.
Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid place, etc.).
If the earth leakage breaker is not installed, it may cause an electric shock.
Inspection and maintenance
When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
Depending upon the conditions of use, an odor may be generated or dirt, dust, etc. may prevent proper drainage.
It is recommended to apply inspection and maintenance (charged) by a specialist in addition to normal maintenance. Consult your dealer.
Also consider operation sound
Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
If abnormal sound is heard during operation, consult your dealer.
Relocation
When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.
Warning:
Repair or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.
Disposal
To dispose of this product, consult your dealer.
If you have any question, consult your dealer.
5. Installation, relocation and inspection
Model
Function
Power supply
Capacity
kW
BTU/h
Input kW
Indoor unit
Airflow (Lo-Hi) CMM
Noise level (Lo-Hi) dB
Weight kg
Outdoor unit
Noise level dB
Refrigerant R410A kg
Weight kg
SLZ-A09AR
Cooling Heating
2.5 3.0
8,500 10,200
0.76 0.87
SLZ-A09AR
8-10
32-38
16.5 + Grille 3
SUZ-A09VR
46
0.8
33
SLZ-A12AR
Cooling Heating
~/N, 220-240V, 50Hz
3.2 3.8
10,900 12,900
1.06 1.07
SLZ-A12AR
9-11
34-39
16.5 + Grille 3
SUZ-A12VR
48
0.9
34
SLZ-A18AR
Cooling Heating
4.3 4.8
14,600 16,300
1.53 1.50
SLZ-A18AR
9-11
35-40
16.5 + Grille 3
SUZ-A18VR
55
1.8
72
Notes: 1. Rating conditions (cooling) Indoor : 27°C DB, 19°C WB Outdoor : 35°C DB
2. Rating conditions (heating) Indoor : 20°C DB Outdoor : 7°C DB, 6°C WB
3. Specifications subject to change without notice.
Guaranteed operating range
Indoor Outdoor
Cooling
Upper limit 32°C DB, 23°C WB 46°C DB,
Lower limit 21°C DB, 15°C WB -10°C DB,
Heating
Upper limit 27°C DB 24°C DB, 18°C WB
Lower limit 20°C DB -10°C DB, -11°C WB
Units should be installed by licensed electric contractor accordingly to local code requirement.
6. Specifications