Master Lock B150CEH Air Conditioner User Manual


 
4
105398
PORTABLE FORCED AIR HEATERS
R
Screw
Wheel
Support
Frame
Wheel
Cap Nut
Nut
Extended
Hub
Front Handle
Axle
Rear
Handle
Air
Inlet
Fuel Tank
Flange
Hot Air
Outlet
ASSEMBLY
(FOR B100CEH AND
B150CEH MODELS ONLY)
These models are furnished with wheels and
handles. Wheels, handles, and the mounting
hardware are found in the shipping carton.
Tools Needed
Medium Phillips Screwdriver
3/8" Open or Adjustable Wrench
Hammer
1. Slide axle through wheel support
frame. Install wheels on axle.
IMPORTANT:
When installing wheels,
point extended hub of wheels toward
wheel support frame (see Figure 3).
Figure 3 - Wheel and Handle Assembly
2. Place cap nuts on axle ends. Gently tap
with hammer to secure.
3. Place heater on wheel support frame.
Make sure air inlet end (rear) of heater
is over wheels. Line up holes on fuel
tank flange with holes on wheel sup-
port frame.
4. Place front handle and rear handle on
top of fuel tank flange. Insert screws
through handles, fuel tank flange, and
wheel support frame. Attach nut finger
tight after each screw is inserted.
5. After all screws are inserted, tighten
nuts firmly.
VENTILATION
WARNING: Follow the mini-
mum fresh, outside air ventilation
requirements. If proper fresh, out-
side air ventilation is not provided,
carbon monoxide poisoning can
occur. Provide proper fresh, out-
side air ventilation before running
heater.
Provide a fresh air opening of at least 2800
square cm (three square feet) for each 30kw
(100,000 Btu/Hr) rating. Provide extra fresh
air if more heaters are being used.
Example:
A 44kw (150,000 Btu/Hr) heater
requires one of the following:
a two-car garage door [4.9 meter (16 feet)
opening] raised 9 cm (3.5 inches)
a single-car garage door [2.75 meter (9
feet) opening] raised 15.25 cm (6 inches)
two, 76 cm (30 inch) windows raised 28
cm (11 inches)