Master Lock 100000 BTU/Hr Electric Heater User Manual


 
8
101585
OPERATION
Continued
To Stop Heater
1. Unplug power cord from outlet.
To Restart Heater
1. Wait 2 minutes after stopping heater.
2. Repeat steps under To Start Heater, page 7.
1. Drain fuel tank.
Note:
Some models have drain plug on underside of fuel tank. If so, remove
drain plug to drain all fuel. If heater does not have drain plug, drain fuel through
fuel cap opening. Be sure all fuel is removed.
2. Replace drain plug if used.
3. Add one gallon (4 liters) of clean kerosene to fuel tank.
4. Attach fuel cap.
5. Move heater forwards and backwards to stir fuel.
6. Remove fuel cap or drain plug and drain fuel tank. Be sure all fuel is removed.
7. Replace fuel cap or drain plug. Properly dispose of old and dirty fuel.
8. Store heater in dry place. Make sure storage place is free of dust and corrosive
fumes.
IMPORTANT:
Do not store kerosene over summer months for use during next
heating season. Using old fuel could damage heater.
STORAGE
PREVENTATIVE
MAINTENANCE
SCHEDULE
Item How Often How To
Fuel tank Flush every 150-200 hours See Storage above.
of operation or as needed.
Air output and Replace every 500 hours of See Air Output, Air Intake,
lint lters operation or once and Lint Filters, page 12.
a year.
Air intake Wash and dry with soap and See Air Output, Air Intake,
lter water every 500 hours of and Lint Filters, page 12.
operation or as needed.
Fuel lter Clean twice a heating season See Fuel Filter, pages 10
or as needed. and 11.
Spark plug Clean and regap every 600 See Spark Plug, page 11.
hours operation or replace
as needed.
Fan blades Clean every season or as needed. See Fan, page 15.
Motor Not required/permanently
lubricated
WARNING
Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.