INSTALLATION PROCEDURE
Figure B.7: GB843 (cover off)
1. Open the housing using a small flat-head screwdriver to separate the
base from the cover.
2. Remove the insulator separating the battery from the contacts on the
battery holder. When you apply power and the Tamper switch is open,
the GB843 enters Test mode during which a transmission is sent every
few seconds. You can terminate Test mode by closing the Tamper
switch. Test mode is automatically terminated after approximately five
minutes.
3. From the Programming menu, select Devices, Zones [911].
4. Select the zone to which you want to register the transmitter; the system
initiates Registration mode. When Save? appears on the panel’s LCD
display, press
3.
5. After registration, press the GB843’s tamper switch to terminate Test
mode.
6. Choose a suitable mounting location according to the guidelines in the
previous section.
7. Before permanently mounting the unit, test the acoustic sensor and the
transmitter from the exact mounting position. For further information on
testing the acoustic sensor, refer to the following section, Hand Clap
Test.
8. Knock out the required mounting holes on the back cover.
9. Mount the unit to the wall using the mounting screws provided.
10. Write the number of the zone on the sticker provided and affix the
sticker inside the front cover for future reference.
11. Close the front cover making sure that it snaps shut.
Tamper
Switch
Battery
Holder
Antenna
Terminal
Block
LED
Indicator
Mounting
Knockout
Mounting
Knockout
Acoustic
Sensor