Manitowoc Ice RF1200W Water System User Manual


 
Manitowoc Ice
2110 South 26
th
Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA 000007058
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 Rev 01
Web Site - www.manitowocice.com
18. Prepare for brazing by blowing residual water out of condenser to extent possible
19. Swage both water connections on condenser
20. From kit, find copper tube with flare nut. From front of machine, feed flare nut end of copper tube
between compressor and vertical white plastic ice tube to bottom condenser connection. Finger tighten
flare nut to 45 elbow. Hold opposite tube end beside bottom condenser connection. Mark tube and
cut to length. Install tube end into swaged connection. Tighten flare nut securely to 45 elbow
21. From kit, find copper tube with winged adapter. From back of machine, feed copper tube thru inner
most round hole in back panel to top condenser connection. Hold tube end beside top condenser
connection. Mark tube and cut to length. Install tube end into swaged connection. Fasten winged
adapter to back panel with 2 screws and nuts from kit; tighten securely
22. Apply wet sponge/rag as necessary to protect refrigeration lines and insulation. Braze two connections
on condenser
23. Feed solenoid valve into remaining square hole in back panel, install screws and tighten securely
24. Feed black plastic drain manifold into remaining round hole in back panel, install screws and tighten
securely
25. Install grille and panels
26. Connect power, condenser supply/drain, potable water supply/drain
27. Renumber water connections on back panel label from 1,2,3,4,5 to 2,1,4,3,5
BEFORE AFTER